Keil project:
MDK-ARM/DM_6220.uvprojx
Target: DM_6220
Output: MDK-ARM/DM_6220/DM_6220.hex
| Axis | Motor ID | Bus | MCU pins | Power output |
|---|---|---|---|---|
| YAW | 0x01 |
CAN1 / FDCAN1 | PD0 RX / PD1 TX | PC14 / OUT1 |
| Pitch | 0x02 |
CAN2 / FDCAN2 | PB5 RX / PB6 TX | PC13 / OUT2 |
LCD is the 1.69 inch ST7789 screen in landscape mode. The LCD data path is now SPI1 with an LVGL partial draw buffer:
LCD_W = 280
LCD_H = 240
PB3=SCK, PD7=SDA, PE15=CS, PD10=DC, PB11=RES, PB10=BLK
The 5-way navigation key follows the dm-mc02-master/例程/CtrBoard-H7_KEY
example. It is an ADC resistor-key module, not five independent GPIO inputs.
ADC1 rank 1: PC4 / ADC1_INP4 board voltage sample
ADC1 rank 2: PA5 / ADC1_INP19 5-way key sample
Sampling: polled every 10 ms in GimbalKeys_Task
Key ADC thresholds:
CENTER < 200
DOWN 700..1000
UP 1500..1800
RIGHT 2200..2500
LEFT 2800..3500
The first screen is the LVGL main menu.
Global center-key actions:
- Center long press, about 800 ms: smooth center home from menu pages.
- Center 3 s in
Manual Jog: save both motor zero positions. - Center very long press, about 5000 ms: emergency stop trajectory and disable both motors.
Menu:
- Up / Down: select item.
- Left: go back.
- Right or Center: enter or confirm.
- In parameter edit: Up/Right increases, Down/Left decreases, Center saves.
Main menu pages:
Run Mode: Stop Motors, MIT Circle, Manual Jog, Center Home.MIT Params: KP, KD, Torque FF, Amp YAW, Amp Pitch, Period, Reset Default.Motor: enable/disable, single-axis enable, OUT1/OUT2 power toggle.Display: backlight on/off and orientation info.About: CAN ID, wiring and build notes.
Zero / Calib is intentionally not a standalone page. To prevent accidental
zero writes, enter Run Mode -> Manual Jog, manually position the two axes,
then hold Center for about 3 s. The firmware only sends both save-zero frames
when both motors are online.
The main loop still sends MIT frames on a 1 ms tick. LVGL runs from the main
loop at 20 ms intervals and uses a partial buffer. During LCD flush chunks,
DisplayServiceDuringFlush services pending motor commands and the 1 ms MIT
send path, so screen drawing does not starve the motors.
Default conservative MIT parameters:
KP = 1.0
KD = 0.08
Torque FF = 0.0
Yaw amp = 10 deg
Pitch amp = 10 deg
Period = 1000 ms
Limits:
KP 0..50
KD 0..2
Torque FF -1..1
Amplitude 0..45 deg
Period 500..5000 ms
Zero-save safety:
- Save-zero is only reachable from
Manual Jogby holding Center for about 3 s. - The command is blocked if either motor is offline.
- Save-zero switches mode to
CTRL_STOPbefore sending special motor command frames. - Enable/Disable/Save-zero commands are treated as protected motor command frames. MIT output is paused while such a request is pending and briefly after the command is accepted by FDCAN, so the special CAN frame is not immediately overwritten by normal position control frames.
- Put the mechanism at the desired mechanical center before holding Center.
- Keep
SAVE_ZERO_ON_BOOTinCore/Inc/main.hat0for normal operation.
The vendored LVGL files are under Middlewares/LVGL. A local zip backup is
kept outside this repository at:
../lvgl_cache/lvgl-v9.2.2-gimbal-vendor.zip
Restore from this cache before downloading LVGL again.