Skip to content

Failed to process tick: missing global report #205

Description

@SamuelPelissier

Hello,

When trying to ingest HWPC data, I am faced with an unexplained behavior.

As far as I can tell, the formula generally works. However, looking at smartwatt's container logs more precisely, I can find:

{"log":"2025-03-20 14:45:01,938 - 64 - ('cpu_dispatcher', 'powerapi/hwpc-sensor', '0') - root - ERROR - Failed to process tick 2025-03-11 12:47:56.060000: missing global report\n","stream":"stderr","time":"2025-03-20T14:45:01.938561318Z"}
{"log":"2025-03-20 14:45:01,939 - 64 - ('cpu_dispatcher', 'powerapi/hwpc-sensor', '0') - root - DEBUG - received message: HWPCReport(2025-03-11 12:47:56.060000, powerapi/hwpc-sensor, all)\n","stream":"stderr","time":"2025-03-20T14:45:01.939076312Z"}

It seems that processing the tick failed due to the lack of global report and I would guess "global report" corresponds to the all target, parsed right afterwards. Are these assumptions sound?

For completeness:

  1. HWPC data corresponding to this tick (groups removed due to length):
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d3"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"59d6190c-e5e0-4996-ac48-f04f61130412-4"}
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d4"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"59d6190c-e5e0-4996-ac48-f04f61130412-5"}
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d5"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"59d6190c-e5e0-4996-ac48-f04f61130412-2"}
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d6"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"59d6190c-e5e0-4996-ac48-f04f61130412-1"}
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d7"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"59d6190c-e5e0-4996-ac48-f04f61130412-3"}
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d8"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"powerapi_hwpc"}
{"_id":{"$oid":"67d030fc6b88dcf0bb5e39d9"},"timestamp":{"$date":"2025-03-11T12:47:56.06Z"},"sensor":"powerapi/hwpc-sensor","target":"all"}
  1. Smartwatts configuration file:
{
    "verbose": true,
    "stream": false,
    "input": {
      "puller": {
        "model": "HWPCReport",
        "type": "mongodb",
        "uri": "mongodb://x:y@z:4242",
        "db": "tmp_db_sensor",
        "collection": "hwpc_report"
      }
    },
    "output": {
      "pusher_power":{
        "model": "PowerReport",
        "type": "csv",
        "directory": "/home/powerapi/"
      }
    },
    "cpu-base-freq": 1100,
    "disable-dram-formula": true,
    "sensor-reports-frequency": 500
}

Thank you in advance!

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions