@pdemeyer pdemeyer commented Jan 7, 2020

Gas metering differs slightly between the Dutch meters and the Flemish (Fluvius) meters.
In NL the OBIS reference is: 0-1:24.2.1 (temperature converted)
In B the OBIS reference is: 0-1:24.2.3 (non-temperature converted)

Gas metering differs slightly between the Dutch meters and the Flemish (Fluvius) meters. 
In NL the OBIS reference is: 0-1:24.2.1 (temperature converted)
In B the OBIS reference is: 0-1:24.2.3 (non-temperature converted)
@rvdbreemen
Copy link

rvdbreemen commented Jan 7, 2020

There are more fields that changed in the belgium extention. See PR I made just now. For example, the version ID in Belgium is 5 chars. So I suggest not to add a value, but to make a belgium namespace with their fields definition, based on fluvius exstentions for belgium