Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Update analog-io.md #2445

Open
wants to merge 1 commit into
base: main
Choose a base branch
from
Open
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
8 changes: 4 additions & 4 deletions content/micropython/01.basics/01.analog-io/analog-io.md
Original file line number Diff line number Diff line change
Expand Up @@ -167,9 +167,9 @@ Let's take a look at what's included in this code example:

The resolution of an ADC can simply be explained as how detailed it is. When using MicroPython, the default is **16-bits**, while using the Arduino programming language it is **10-bits**. So what is the difference?

When we read something in 16-bit resolution, we receive a range of 0-65355. Let's say the voltage range is 0-3.3V, as is standard in most modern boards. If we were to read 3.3V, it means "max" or "65355". If we read half of that voltage (1.65V), it would be 65355/2 = 32677.
When we read something in 16-bit resolution, we receive a range of 0-65535. Let's say the voltage range is 0-3.3V, as is standard in most modern boards. If we were to read 3.3V, it means "max" or "65535". If we read half of that voltage (1.65V), it would be 65535/2 = 32767.

Now let's say we have an analog sensor reading temperature. If the temperature is at its very max for that component, and it outputs 3.3V, we will read 65355. If it is not outputting any voltage (which is unlikely), we would read 0.
Now let's say we have an analog sensor reading temperature. If the temperature is at its very max for that component, and it outputs 3.3V, we will read 65535. If it is not outputting any voltage (which is unlikely), we would read 0.

If we are using a different resolution, such as **10-bits**, the range would instead be **0-1023**. The voltage remains the same, but the value we read is different.

Expand All @@ -179,9 +179,9 @@ Why does it work this way? See, bits are used to represent information. A single
- 4-bits = 0-8
- 8-bits = 0-255
- 10-bits = 0-1023
- 16-bits = 0-65355
- 16-bits = 0-65535
- 32-bits = 0-4,294,967,295

## Summary

In this guide we have learned about analog inputs, outputs & resolution. We have also gone through a number of fundamental examples to understand how it works in practice.