3 changes: 2 additions & 1 deletion src/EnergyPlus/DataRuntimeLanguage.hh
Original file line number Diff line number Diff line change
Expand Up @@ -394,9 +394,10 @@ namespace DataRuntimeLanguage {
ErlValueType Value; // values taken by Erl variables
bool ReadOnly; // true if Erl variable is read-only
bool SetByExternalInterface; // set to true if value is set by ExternalInterface
bool SetByGlobalVariable;

// Default Constructor
ErlVariableType() : StackNum(0), ReadOnly(false), SetByExternalInterface(false)
ErlVariableType() : StackNum(0), ReadOnly(false), SetByExternalInterface(false), SetByGlobalVariable(false)
{
}
};
Expand Down
6 changes: 4 additions & 2 deletions src/EnergyPlus/RuntimeLanguageProcessor.cc
Original file line number Diff line number Diff line change
Expand Up @@ -816,7 +816,6 @@ ErlValueType EvaluateStack(EnergyPlusData &state, int const StackNum)
ReturnValue.Number = 0.0;

auto const &thisErlStack = state.dataRuntimeLang->ErlStack(StackNum);

InstructionNum = 1;
while (InstructionNum <= thisErlStack.NumInstructions) {

Expand Down Expand Up @@ -1801,7 +1800,8 @@ ErlValueType EvaluateExpression(EnergyPlusData &state, int const ExpressionNum,
} else { // value has never been set
ReturnValue.Type = Value::Error;
ReturnValue.Error = "EvaluateExpression: Variable = '" + thisErlVar.Name + "' used in expression has not been initialized!";
if (!state.dataGlobal->DoingSizing && !state.dataGlobal->KickOffSimulation && !state.dataEMSMgr->FinishProcessingUserInput) {

if ((!state.dataGlobal->DoingSizing && !state.dataGlobal->KickOffSimulation && !state.dataEMSMgr->FinishProcessingUserInput) || (!thisErlVar.SetByGlobalVariable)) {

// check if this is an arg in CurveValue,
if (thisErlExpression.Operator !=
Expand Down Expand Up @@ -2972,6 +2972,8 @@ void GetRuntimeLanguageUserInput(EnergyPlusData &state)
// Initialize variables for the ExternalInterface variables.
// This object requires an initial value.
ExternalInterfaceInitializeErlVariable(state, VariableNum, SetErlValueNumber(rNumericArgs(1)), false);
} else {
state.dataRuntimeLang->ErlVariable(VariableNum).SetByGlobalVariable = true;
}
}
}
Expand Down
2 changes: 2 additions & 0 deletions src/EnergyPlus/SimulationManager.cc
Original file line number Diff line number Diff line change
Expand Up @@ -268,6 +268,7 @@ namespace SimulationManager {
state.dataGlobal->KickOffSimulation = true;

Weather::ResetEnvironmentCounter(state);

SetupSimulation(state, ErrorsFound);

FaultsManager::CheckAndReadFaults(state);
Expand Down Expand Up @@ -330,6 +331,7 @@ namespace SimulationManager {
ReportNodeConnections(state);
}
SystemReports::CreateEnergyReportStructure(state);

bool anyEMSRan;
// point to finish setup processing EMS, sensor ready now
EMSManager::ManageEMS(state, EMSManager::EMSCallFrom::SetupSimulation, anyEMSRan, ObjexxFCL::Optional_int_const());
Expand Down
176 changes: 175 additions & 1 deletion tst/EnergyPlus/unit/EMSManager.unit.cc
Original file line number Diff line number Diff line change
Expand Up @@ -52,6 +52,7 @@

// EnergyPlus Headers
#include "Fixtures/EnergyPlusFixture.hh"
#include <EnergyPlus/ConfiguredFunctions.hh>
#include <EnergyPlus/Construction.hh>
#include <EnergyPlus/CurveManager.hh>
#include <EnergyPlus/Data/EnergyPlusData.hh>
Expand Down Expand Up @@ -936,7 +937,7 @@ TEST_F(EnergyPlusFixture, TestUnInitializedEMSVariable2)
state->dataEMSMgr->FinishProcessingUserInput = true;
bool anyRan;
EMSManager::ManageEMS(*state, EMSManager::EMSCallFrom::SetupSimulation, anyRan, ObjexxFCL::Optional_int_const());
// Expect the variable to not yet be initialized, call EvaluateExpresssion and check argument
// Expect the variable to not yet be initialized, call EvaluateExpression and check argument

ErlValueType ReturnValue;
bool seriousErrorFound = false;
Expand All @@ -958,6 +959,179 @@ TEST_F(EnergyPlusFixture, TestUnInitializedEMSVariable2)
EXPECT_FALSE(seriousErrorFound);
}

TEST_F(EnergyPlusFixture, TestEMSVariableInitAfterRef1)
{
// test for #11360 - EMS variable initialized after reference, outside of ManageSimulation
std::string const idf_objects = delimited_string({

"EnergyManagementSystem:Program,",
" ev_discharge_program, !- Name",
" Set power_mult = site_temp_adj, !- Program Line 1",
" Set site_temp_adj = 0.1; !- Program Line 2",

"EnergyManagementSystem:ProgramCallingManager,",
" ev_discharge_pcm, !- Name",
" BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point",
" ev_discharge_program; !- Program Name 1",
});

ASSERT_TRUE(process_idf(idf_objects));
state->init_state(*state);

int internalVarNum = RuntimeLanguageProcessor::FindEMSVariable(*state, "site_temp_adj", 1);
EXPECT_EQ(internalVarNum, 0);

bool anyRan;
EXPECT_TRUE(state->dataEMSMgr->GetEMSUserInput);
EMSManager::ManageEMS(*state, EMSManager::EMSCallFrom::SetupSimulation, anyRan, ObjexxFCL::Optional_int_const());

internalVarNum = RuntimeLanguageProcessor::FindEMSVariable(*state, "site_temp_adj", 1);
ASSERT_GT(internalVarNum, 0);
EXPECT_FALSE(state->dataRuntimeLang->ErlVariable(internalVarNum).Value.initialized);

EXPECT_FALSE(state->dataEMSMgr->GetEMSUserInput);
EMSManager::ManageEMS(*state, EMSManager::EMSCallFrom::BeginNewEnvironment, anyRan, ObjexxFCL::Optional_int_const());

internalVarNum = RuntimeLanguageProcessor::FindEMSVariable(*state, "site_temp_adj", 1);
ASSERT_GT(internalVarNum, 0);
EXPECT_FALSE(state->dataRuntimeLang->ErlVariable(internalVarNum).Value.initialized);

EXPECT_FALSE(state->dataEMSMgr->GetEMSUserInput);
ASSERT_THROW(EMSManager::ManageEMS(*state, EMSManager::EMSCallFrom::BeginTimestepBeforePredictor, anyRan, ObjexxFCL::Optional_int_const()), EnergyPlus::FatalError);

internalVarNum = RuntimeLanguageProcessor::FindEMSVariable(*state, "site_temp_adj", 1);
ASSERT_GT(internalVarNum, 0);
EXPECT_FALSE(state->dataRuntimeLang->ErlVariable(internalVarNum).Value.initialized);

// Expect the variable to not yet be initialized, call EvaluateExpression and check argument
bool seriousErrorFound = false;
ErlValueType ReturnValue = RuntimeLanguageProcessor::EvaluateExpression(
*state,
state->dataRuntimeLang->ErlStack(Util::FindItemInList("EV_DISCHARGE_PROGRAM", state->dataRuntimeLang->ErlStack)).Instruction(1).Argument2,
seriousErrorFound);
EXPECT_TRUE(seriousErrorFound);

const std::string expected_error = delimited_string({
" ** Severe ** Problem found in EMS EnergyPlus Runtime Language.",
" ** ~~~ ** Erl program name: EV_DISCHARGE_PROGRAM",
" ** ~~~ ** Erl program line number: 1",
" ** ~~~ ** Erl program line text: SET POWER_MULT = SITE_TEMP_ADJ",
" ** ~~~ ** Error message: *** Error: EvaluateExpression: Variable = 'SITE_TEMP_ADJ' used in expression has not been initialized! *** ",
" ** ~~~ ** Environment=, at Simulation time= 00:-15 - 00:00",
" ** Fatal ** Previous EMS error caused program termination.",
" ...Summary of Errors that led to program termination:",
" ..... Reference severe error count=1",
" ..... Last severe error=Problem found in EMS EnergyPlus Runtime Language.",
});

compare_err_stream(expected_error);
}

TEST_F(EnergyPlusFixture, TestEMSVariableInitAfterRef2)
{
// test for #11360 - EMS variable initialized after reference, within ManageSimulation
std::string const idf_objects = delimited_string({
"Version," + DataStringGlobals::MatchVersion + ";",

"RunPeriod,",
" Run Period 1, !- Name",
" 1, !- Begin Month",
" 1, !- Begin Day of Month",
" 2007, !- Begin Year",
" 1, !- End Month",
" 1, !- End Day of Month",
" 2007, !- End Year",
" Monday, !- Day of Week for Start Day",
" No, !- Use Weather File Holidays and Special Days",
" No, !- Use Weather File Daylight Saving Period",
" No, !- Apply Weekend Holiday Rule",
" Yes, !- Use Weather File Rain Indicators",
" Yes; !- Use Weather File Snow Indicators",

"SimulationControl,",
" No, !- Do Zone Sizing Calculation",
" No, !- Do System Sizing Calculation",
" No, !- Do Plant Sizing Calculation",
" No, !- Run Simulation for Sizing Periods",
" Yes, !- Run Simulation for Weather File Run Periods",
" , !- Do HVAC Sizing Simulation for Sizing Periods",
" ; !- Maximum Number of HVAC Sizing Simulation Passes",

"Site:Location,",
" Denver Stapleton Intl Arpt CO USA WMO=724690, !- Name",
" 39.77, !- Latitude {deg}",
" -104.87, !- Longitude {deg}",
" -7.00, !- Time Zone {hr}",
" 1611.00; !- Elevation {m}",

"Material,",
" Concrete Block, !- Name",
" MediumRough, !- Roughness",
" 0.1014984, !- Thickness {m}",
" 0.3805070, !- Conductivity {W/m-K}",
" 608.7016, !- Density {kg/m3}",
" 836.8000; !- Specific Heat {J/kg-K}",

"Construction,",
" ConcConstruction, !- Name",
" Concrete Block; !- Outside Layer",

"BuildingSurface:Detailed,"
" Wall, !- Name",
" Wall, !- Surface Type",
" ConcConstruction, !- Construction Name",
" Zone, !- Zone Name",
" , !- Space Name",
" Outdoors, !- Outside Boundary Condition",
" , !- Outside Boundary Condition Object",
" SunExposed, !- Sun Exposure",
" WindExposed, !- Wind Exposure",
" 0.5000000, !- View Factor to Ground",
" 4, !- Number of Vertices",
" 0.000000,0.000000,10.00000, !- X,Y,Z ==> Vertex 1 {m}",
" 0.000000,0.000000,0, !- X,Y,Z ==> Vertex 2 {m}",
" 10.00000,0.000000,0, !- X,Y,Z ==> Vertex 3 {m}",
" 10.00000,0.000000,10.00000; !- X,Y,Z ==> Vertex 4 {m}",

"Zone,"
" Zone, !- Name",
" 0, !- Direction of Relative North {deg}",
" 6.000000, !- X Origin {m}",
" 6.000000, !- Y Origin {m}",
" 0, !- Z Origin {m}",
" 1, !- Type",
" 1, !- Multiplier",
" autocalculate, !- Ceiling Height {m}",
" autocalculate; !- Volume {m3}",

"EnergyManagementSystem:Program,",
" ev_discharge_program, !- Name",
" Set power_mult = site_temp_adj, !- Program Line 1",
" Set site_temp_adj = 0.1; !- Program Line 2",

"EnergyManagementSystem:ProgramCallingManager,",
" ev_discharge_pcm, !- Name",
" BeginTimestepBeforePredictor, !- EnergyPlus Model Calling Point",
" ev_discharge_program; !- Program Name 1",
});

ASSERT_TRUE(process_idf(idf_objects));
state->init_state(*state);

state->dataWeather->WeatherFileExists = true;
state->files.inputWeatherFilePath.filePath = configured_source_directory() / "weather/USA_CO_Golden-NREL.724666_TMY3.epw";

int internalVarNum = RuntimeLanguageProcessor::FindEMSVariable(*state, "site_temp_adj", 1);
EXPECT_EQ(internalVarNum, 0);

EXPECT_TRUE(state->dataEMSMgr->GetEMSUserInput);
ASSERT_THROW(SimulationManager::ManageSimulation(*state), EnergyPlus::FatalError);

internalVarNum = RuntimeLanguageProcessor::FindEMSVariable(*state, "site_temp_adj", 1);
ASSERT_GT(internalVarNum, 0);
EXPECT_FALSE(state->dataRuntimeLang->ErlVariable(internalVarNum).Value.initialized);
}

TEST_F(EnergyPlusFixture, EMSManager_CheckIfAnyEMS_OutEMS)
{
std::string const idf_objects = delimited_string({
Expand Down
Loading