Notifications
You must be signed in to change notification settings - Fork 0
/
Copy path4-DLVR-L30D.fth
156 lines (129 loc) · 5.72 KB
/
4-DLVR-L30D.fth
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
\ DLVR-L30D Driver, DLVR-L30D.fth
\ V0.1 dp 151106 2200
\ DLVR-L30D E1BD-C N13N +- 30 psi pressure sensor
\ 3.3 Volt, I2C Interface
\ USAGE: call PSI@ to get ( -- result inches 10ths )
\ call PSI.GET in main program keypoll to run the sensor and accumulate results
\ change log
\ 151107 dp working on transfer functions for temp and psi
\ 151108 kty fixed math and bit masks 151108.1400 V0.3
\ 160807 dp added PSI@ word for production 160807.23:00 V0.4
\ 160809 dp modified PSI@ to return ( --- status psi ) to test for reading or sensor failure V0.5
\ 160812 dp made pressure driver into a TASK that can be stopped and started.
\ added circ buffers to avg last 16 readings into DPAVG longs V.06
\ 160813 dp tested for condition Status 0 and -8192, sensor grounded, tuned timing better sensor comms V.07
\ 160814 dp got sensor working 90%, need to improve I2C-ish "signaling" V.08 release 1. Use runit to test
\ 160822 dp using new extend.fth resolve errors of I2C arbitration V1.1
\ 160823 dp okay complete rewrite to remove this module as a task and it is used in keypoll to read,
\ accumulate, error check and condition data for use in PSI@ word. V1.2
\ 160830 dp Peter found a bug, I was sending an ACK on the 4th byte instead of NAK, this routine is now called by a timer in GardenControl.fth
\ 161008 dp,kty Divide pressure by 2 for differential sensors
\ driver must protect from these errors
\ Status 0 = good data *** OR *** sensor grounded out = Status 0 reading -8192
\ Status 1 = resevered bad data
\ Status 2 = sensor disconnected from power or stale data
\ Status 3 = sensor bad data
\ Status 85 = %01010101 will be returned by this driver when the sensor fails
\ after appropriate retry counts.
TACHYON
FORGET DLVR-L30D.fth
pub DLVR-L30D.fth ." DLVR-L30D PSI Sensor v1.4 1601008.1830" ;
DECIMAL
[~
\ Sensor Data Masks
$C0000000 CONSTANT status \ two bits 31-30
$3FFF0000 CONSTANT psi \ fourteen bits 29-16
$0000FFE0 CONSTANT temp \ eleven bits 15-5 last 5 are empty / unused
\ Sensor Device Address Base $28
$50 CONSTANT psiw \ device address write
$51 CONSTANT psir
\ Result
LONG RESULT
\ Use private I2C Bus
--- EEPROM
#P0 == mSDA
#P1 == mSCL
{ fix up non compliant chip with I2C routines that handle the chip's issues }
pub II2C!? ( data -- flg ) \ write a byte to the I2C bus and return with the ack 0=ack
#24 REV \ put into lsb first format for SHROUT
SDA DUP OUTCLR SWAP \ data masks
8 FOR
SHROUT \ Shift out next data bit
CLOCK NOP CLOCK
NEXT \ loop
DROP DUP INPUTS \ Float SDA
CLOCK IN 0<> CLOCK \ ack clock
;
pub II2C! ( data -- ) \ write a byte to the I2C bus but ignore the ack
#24 REV \ put into lsb first format for SHROUT
SDA DUP OUTCLR SWAP \ data masks
8 FOR \ start loop for 8 times
SHROUT \ Shift out next data bit
CLOCK NOP CLOCK
NEXT \ loop
DROP INPUTS \ Float SDA
CLOCK NOP CLOCK \ dummy ack clock
;
{ read data from the device, free running read only device }
pub DLVR@ ( -- ) \ sets the RESULT long
mSDA mSCL I2CPINS \ use private i2c bus
I2CSTART \ starts the bus
psir II2C!
ackI2C@ 8<<
ackI2C@ OR 8<<
ackI2C@ OR 8<< \ shift into 3RD byte
1 I2C@ OR \ read 4TH byte, DON'T ACK
RESULT ! \ store it
I2CSTOP \ stop the bus
EEPROM
;
\ TASK Allocations
#16 LONGS psibuff --- circ buffer allocation
BYTE psiptr --- buffer pointer
long calval --- set this in GardenControl.fth for sensor calibration/offset
long PSIFLT --- fault code result
LONG DPSI, DSTATUS, DTEMP, DPAVG, DRETRY --- result variables
pub PSI.GET
DLVR@
RESULT @ status AND #30 >> DSTATUS !
RESULT @ psi AND #16 >> #8192 - 1 SHR calval @ + DPSI !
RESULT @ temp AND 5 >> DTEMP !
DSTATUS @ 0= IF
0 DRETRY ! --- reset retry counter
psiptr C@ 15 => --- are we at index 0 - 15
IF
0 psiptr C! --- reset index, write to this index
DPSI @ psibuff ! --- write to 0 location
ELSE
1 psiptr C@ + DUP psiptr C! --- increment buffer ptr save and leave on stack
4 * psibuff + DPSI @ SWAP ! --- write DPSI to this buffer index
THEN
0 16 0 DO I 4 * psibuff + @ + LOOP 16 / DPAVG ! --- computer and write the average to DPAVG
ELSE --- capture error condition to retry cout
1 DRETRY @ + DRETRY ! --- increment the sensor retry max counter
DRETRY @ 20 => IF --- test for max consecutive retries
85 PSIFLT ! --- write the sensor fault status
THEN
THEN
;
pub PSI@ ( -- tenths inches Status )
DPAVG @ 10 / DUP 10 / swap 10 MOD SWAP
PSIFLT @
;
pub PSIDBug@ ( --- Status PSI )
." Status: " DSTATUS @ . CR
." PSI: " DPSI @ . CR
." Avg PSI: " DPAVG @ . CR
." Nrmlzd PSI: " DPAVG @ 10 / DUP 10 / swap 10 MOD SWAP . ." ." . CR
." TEMP: " DTEMP @ . CR
." FAULT: " PSIFLT @ . CR
;
pub clearpsi ( -- ) \ clear the psi buffer
16 0 DO 0 I 4 * psibuff + ! LOOP \ clear the buffer for fun
;
{ ********** test the sensor ********** }
pub showbuff \ show what's in the circular buffer
16 0 DO CR I 4 * psibuff + @ . LOOP
;
]~
END