@@ -108,8 +108,9 @@ for the Dell PowerConnect device::
108108 ngs_switchport_mode = access
109109
110110Dell PowerConnect devices have been seen to have issues with multiple
111- concurrent configuration sessions. See :ref: `synchronization ` for details on
112- how to limit the number of concurrent active connections to each device.
111+ concurrent configuration sessions. See :ref: `synchronization ` and
112+ :ref: `batching ` for details on how to limit the number of concurrent active
113+ connections to each device.
113114
114115for the Brocade FastIron (ICX) device::
115116
@@ -191,8 +192,16 @@ connection URL for the backend should be configured as follows::
191192 [ngs_coordination]
192193 backend_url = <backend URL>
193194
194- The default is to limit the number of concurrent active connections to each
195- device to one, but the number may be configured per-device as follows::
195+ The backend URL format includes the Tooz driver as the scheme, with driver
196+ options passed using query string parameters. For example, to use the
197+ ``etcd3gw `` driver with an API version of ``v3 `` and a path to a CA
198+ certificate::
199+
200+ [ngs_coordination]
201+ backend_url = etcd3+https://etcd.example.com?api_version=v3,ca_cert=/path/to/ca/cert.crt
202+
203+ The default behaviour is to limit the number of concurrent active connections
204+ to each device to one, but the number may be configured per-device as follows::
196205
197206 [genericswitch:device-hostname]
198207 ngs_max_connections = <max connections>
@@ -206,6 +215,35 @@ timeout of 60 seconds before failing. This timeout can be configured as follows
206215 ...
207216 acquire_timeout = <timeout in seconds>
208217
218+ .. _batching :
219+
220+ Batching
221+ ========
222+
223+ For many network devices there is a significant SSH connection overhead which
224+ is incurred for each network or port configuration change. In a large scale
225+ system with many concurrent changes, this overhead adds up quickly. Since the
226+ Antelope release, the Generic Switch driver includes support to batch up switch
227+ configuration changes and apply them together using a single SSH connection.
228+
229+ This is implemented using etcd as a queueing system. Commands are added
230+ to an input key, then a worker thread processes the available commands
231+ for a particular switch device. We pull off the queue using the version
232+ at which the keys were added, giving a FIFO style queue. The result of
233+ each command set are added to an output key, which the original request
234+ thread is watching. Distributed locks are used to serialise the
235+ processing of commands for each switch device.
236+
237+ The etcd endpoint is configured using the same ``[ngs_coordination]
238+ backend_url `` option used in :ref: `synchronization `, with the limitation that
239+ only ``etcd3gw `` is supported.
240+
241+ Additionally, each device that will use batched configuration should include
242+ the following option::
243+
244+ [genericswitch:device-hostname]
245+ ngs_batch_requests = True
246+
209247Disabling Inactive Ports
210248========================
211249