doc/source/configuration.rst

Lines changed: 42 additions & 4 deletions
Original file line numberDiff line numberDiff line change
@@ -108,8 +108,9 @@ for the Dell PowerConnect device::
108108
ngs_switchport_mode = access
109109

110110
Dell PowerConnect devices have been seen to have issues with multiple
111-
concurrent configuration sessions. See :ref:`synchronization` for details on
112-
how to limit the number of concurrent active connections to each device.
111+
concurrent configuration sessions. See :ref:`synchronization` and
112+
:ref:`batching` for details on how to limit the number of concurrent active
113+
connections to each device.
113114

114115
for the Brocade FastIron (ICX) device::
115116

@@ -191,8 +192,16 @@ connection URL for the backend should be configured as follows::
191192
[ngs_coordination]
192193
backend_url = <backend URL>
193194

194-
The default is to limit the number of concurrent active connections to each
195-
device to one, but the number may be configured per-device as follows::
195+
The backend URL format includes the Tooz driver as the scheme, with driver
196+
options passed using query string parameters. For example, to use the
197+
``etcd3gw`` driver with an API version of ``v3`` and a path to a CA
198+
certificate::
199+
200+
[ngs_coordination]
201+
backend_url = etcd3+https://etcd.example.com?api_version=v3,ca_cert=/path/to/ca/cert.crt
202+
203+
The default behaviour is to limit the number of concurrent active connections
204+
to each device to one, but the number may be configured per-device as follows::
196205

197206
[genericswitch:device-hostname]
198207
ngs_max_connections = <max connections>
@@ -206,6 +215,35 @@ timeout of 60 seconds before failing. This timeout can be configured as follows
206215
...
207216
acquire_timeout = <timeout in seconds>
208217

218+
.. _batching:
219+
220+
Batching
221+
========
222+
223+
For many network devices there is a significant SSH connection overhead which
224+
is incurred for each network or port configuration change. In a large scale
225+
system with many concurrent changes, this overhead adds up quickly. Since the
226+
Antelope release, the Generic Switch driver includes support to batch up switch
227+
configuration changes and apply them together using a single SSH connection.
228+
229+
This is implemented using etcd as a queueing system. Commands are added
230+
to an input key, then a worker thread processes the available commands
231+
for a particular switch device. We pull off the queue using the version
232+
at which the keys were added, giving a FIFO style queue. The result of
233+
each command set are added to an output key, which the original request
234+
thread is watching. Distributed locks are used to serialise the
235+
processing of commands for each switch device.
236+
237+
The etcd endpoint is configured using the same ``[ngs_coordination]
238+
backend_url`` option used in :ref:`synchronization`, with the limitation that
239+
only ``etcd3gw`` is supported.
240+
241+
Additionally, each device that will use batched configuration should include
242+
the following option::
243+
244+
[genericswitch:device-hostname]
245+
ngs_batch_requests = True
246+
209247
Disabling Inactive Ports
210248
========================
211249

0 commit comments

Comments
 (0)