package gos7
// Copyright 2018 Trung Hieu Le. All rights reserved.
// This software may be modified and distributed under the terms
// of the BSD license. See the LICENSE file for details.
import (
"time"
)
// Client interface s7 client
type Client interface {
//AGReadDB Read data blocks from PLC
AGReadDB(dbNumber int, start int, size int, buffer []byte) (err error)
// AGWriteDB write data blocks into PLC
AGWriteDB(dbNumber int, start int, size int, buffer []byte) (err error)
// AGReadMB Read Merkers area from PLC
AGReadMB(start int, size int, buffer []byte) (err error)
// AGWriteMB Write Merkers from into PLC
AGWriteMB(start int, size int, buffer []byte) (err error)
// AGReadEB Read IPI from PLC
AGReadEB(start int, size int, buffer []byte) (err error)
// AGWriteEB Write IPI into PLC
AGWriteEB(start int, size int, buffer []byte) (err error)
// AGReadAB Read IPU from PLC
AGReadAB(start int, size int, buffer []byte) (err error)
// AGWriteAB Write IPU into PLC
AGWriteAB(start int, size int, buffer []byte) (err error)
// AGReadTM Read timer from PLC
AGReadTM(start int, size int, buffer []byte) (err error)
// AGWriteTM Write timer into PLC
AGWriteTM(start int, size int, buffer []byte) (err error)
// AGReadCT Read counter from PLC
AGReadCT(start int, size int, buffer []byte) (err error)
// AGWriteCT Write counter into PLC
AGWriteCT(start int, size int, buffer []byte) (err error)
// AGReadMulti multi read area
AGReadMulti(dataItems []S7DataItem, itemsCount int) (err error)
// AGWriteMulti multi write area
AGWriteMulti(dataItems []S7DataItem, itemsCount int) (err error)
// DBFill /*block*/
DBFill(dbnumber int, fillchar int) error
DBGet(dbnumber int, usrdata []byte, size int) error
// Read general read function with S7 sytax
Read(variable string, buffer []byte) (value interface{}, err error)
// GetAgBlockInfo Get block infor in AG area, refer an S7BlockInfor pointer
GetAgBlockInfo(blocktype int, blocknum int) (info S7BlockInfo, err error)
// PLCHotStart Hotstart PLC, Puts the CPU in RUN mode performing an HOT START.
PLCHotStart() error
// PLCColdStart Cold start PLC, change CPU into runmode performing and COLD START
PLCColdStart() error
// PLCStop change CPU to stop mode
PLCStop() error
// PLCGetStatus return CPU status: running/stopped
PLCGetStatus() (status int, err error)
// PGListBlocks list all blocks in PLC, return a Blockslist which contains list of OB, DB, ...
PGListBlocks() (list S7BlocksList, err error)
// SetSessionPassword set the session password for PLC to meet its security level
SetSessionPassword(password string) error
// ClearSessionPassword clear the password set for current session
ClearSessionPassword() error
// GetProtection return the CPU protection level info, refer to: §33.19 of "System Software for S7-300/400 System and Standard Functions"
//return S7Protection and its properties.
GetProtection() (protection S7Protection, err error)
// GetOrderCode get CPU order code, return S7OrderCode
GetOrderCode() (info S7OrderCode, err error)
// GetCPUInfo get CPU info, return S7CpuInfo and its properties
GetCPUInfo() (info S7CpuInfo, err error)
// GetCPInfo get CP info, return S7CpInfo and its properties
GetCPInfo() (info S7CpInfo, err error)
// PGClockRead /*datetime*/
//read clock on PLC, return a time
PGClockRead(datetime time.Time) error
// PGClockWrite write clock to PLC with datetime input
PGClockWrite() (dt time.Time, err error)
IsConnected() bool
}