title | description | addedAt | pageClass |
---|---|---|---|
Legrand 067766 control via MQTT |
Integrate your Legrand 067766 via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2023-02-01 06:45:57 -0800 |
device-page |
Model | 067766 |
Vendor | Legrand |
Description | Centralized ventilation switch |
Exposes | switch (state), action, led_in_dark, led_if_on, power_on_behavior, linkquality |
Picture |
This device supports OTA updates, for more information see OTA updates.
How to use device type specific configuration
identity_effect
: Defines the identification effect to simplify the device identification. Example:
identity_effect:
effect: blink 3 # allowed: 'blink 3', 'fixed', 'blink green', 'blink blue'
color: red # allowed: 'default', 'red', 'green', 'blue', 'lightblue', 'yellow', 'pink', 'white'
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
The current state of this switch is in the published state under the state
property (value is ON
or OFF
).
To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
.
To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on.
Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands.
Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work
Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It's not possible to read (/get
) or write (/set
) this value.
The possible values are: identify
.
Enables the built-in LED allowing to see the switch in the dark.
Value can be found in the published state on the led_in_dark
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"led_in_dark": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"led_in_dark": NEW_VALUE}
.
If value equals ON
led in dark is ON, if OFF
OFF.
Enables the LED on activity.
Value can be found in the published state on the led_if_on
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"led_if_on": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"led_if_on": NEW_VALUE}
.
If value equals ON
led if on is ON, if OFF
OFF.
Controls the behavior when the device is powered on after power loss. If you get an UNSUPPORTED_ATTRIBUTE
error, the device does not support it..
Value can be found in the published state on the power_on_behavior
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"power_on_behavior": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"power_on_behavior": NEW_VALUE}
.
The possible values are: off
, previous
, on
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.