Here are some manual steps to follow in order to perform some basic behavior testing of the tool. For each test, each manual steps and a typical output will be described for validation. These tests are based on the Release 1.1 structure of Tootsea.
- Testing steps :
File/Import datafile/SBE3X_Parser- Open
Data_Test/SBE/ov05-mc4008.asc - On the 1st axes of the main figure, select
TEMP - Click the
+button in the bottom right to add an axes - Select
CNDCin this new axes - Add another axes and select
PRES_REL
- Expected results :
- 3 axes should be visible with
TEMP,CNDCandPRES_RELdisplayed. - With the tools in the top menu bar, you should be able to zoom in/out and pan, with all 3 axes synchronized.
- The added axes can be removed, but not the first one
- 3 axes should be visible with
- Prerequisite : Test n°1
- Testing steps :
Corrections/Subserie- In the bottom left menu, select
PRES_RELto change the displayed serie - With the
zoom intool, you can zoom on a part of the serie to check precisely your new serie limits. Then clickSet L1, and double-click where you want to set your new start time. A red line should appear and the first date box is set. - Repeat the operation for the new end date of your serie with
Set L2. - Date boxes are editable in necessary to adjust new limits. If you do so, a green line should appear in the new limits. Set limits to : * 26/09/05-20:00 * 19/06/06-20:00
- You can set the suffix of your new series, by default it's
_sub. - In the left menu, select all 3 variables (
CTRL+AorCTRL+CLICK), and clickSave
- Expected results :
- The
Subseriewindow should be closed. - 3 new series should be available in the
Time Seriesmenu and in the plotting menu of each axes available.
- The
- Prerequisite : Test n°1
- Testing steps :
Edit/New Parameter- Click
DEPTHin the top menu to pre-load the corresponding code. - Click
Evaluateto check if the creation code runs. Bottom log console should turn red becauseLatitudeis not defined - Replace
Latitudeby55.0 - Click
Evaluate, it should turn green and the newDEPTHshould appear in the left menu. - Repeat the operation for
PSALvariable and clickClose
- Expected results :
- The
New Parameterwindow should be closed - 2 new series should be available in the
Time Seriesmenu and in the plotting menu of each axes available.
- The
- Prerequisite : Test n°1
- Testing steps :
Plots/Stats/Histogram- Select
1 dimension,TEMPin the 1st variable menu andAll data. - Set first limits to 3 / 7, and set the
Bin numberto 50 - Click
Plot
- Expected results :
- The distribution of the measured temperature between 3°C and 7°C
- Other testing steps :
- Select
2 dimensions,TEMPin the 1st variable menu,CNDCin the 2nd andAll data. - Set first limits (
TEMP) to3 / 7, and second (CNDC) to3 / 3.7. - Then, instead of setting the number of bins, set the bin size to
0.1for x (TEMP) and0.01for y (CNDC) - Click
Plot
- Select
- Expected results :
- The 2D distribution of the conductivity function of temperature
- Prerequisite : Test n°1
- Testing steps :
Edit/Edit Metadata- Click on
+button to add many lines as you wish. - Fill
PropertiesandValues, for the lines you created - Click
Save
- Expected results :
- The
Edit Metadatawindow should be closed - New meta should be available in the
MetaDatamenu of the main figure.
- The
- Prerequisite : Test n°1
- Testing steps :
Edit/Edit Parameters- Select
PRES_RELin the variable menu and clickeditto activate edition mode. - Change the name of the variable to
PRESand theFillValuetoNaN - Click
ok, the variable menu should turn green. - Click
Save & Close
- Expected results :
- In the
Time Seriesmenu, the variable should appear with its new name. Other modified properties are stored for future netcdf export.
- In the
- Prerequisite : Test n°1
- Testing steps :
File/Session/Save(orfloppy diskicon)- Save your
.matfile where you want File/Resetto relaunchTootseaFile/Session/Loadto load your previous session- Select the
.matfile you just saved
- Expected results :
- Your created series should be back in the
Time Seriesmenu. - Meta data created previously should be back in the
MetaDatamenu.
- Your created series should be back in the
- Prerequisite : Test n°1
- Testing steps :
File/Export/Netcdf- Check if mandatory MetaData are filled ("
Latitude", "Longitude") (seeTest n°5). If not (MetaData in red), please complete MetaData. - Add some variables to the netcdf by selecting variable in the left menu and clicking
Add. It will ask you to add QC. - Click
Save file, it will ask you where you want to save your file.
- Expected results :
- A netcdf file should be created, as well as a validation message.