Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathenergy_logger.py
159 lines (127 loc) · 5.35 KB
/
energy_logger.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
#!/usr/bin/env python
# -*- coding: utf_8 -*-
"""
energy_logger: Sharp JH-1600E grid connect solar inverter data logger
(C)2010 - Mike Cornelius - [email protected]
This file is distributed under GNU GPL license, see license.txt
"""
import sys
import time
import serial
import subprocess
import syslog
import logging
from time import localtime, strftime
import modbus_tk
import modbus_tk.defines as cst
import modbus_tk.modbus_rtu as modbus_rtu
from elogger_config import *
from jh1600e import *
logger = modbus_tk.utils.create_logger(LOGGER)
class logger_runtime:
def __init__(self):
self.p_accm = 0
self.p_count = 0
self.p_max = 0
self.p_max_time = localtime()
self.status_sent = False
self.output_sent = False
def poll_jh1600e_stats(mb):
stats = jh1600e_stats()
#Poll dynamic stats multiple times to get both AC and DC stats
while stats.read_groups != 3:
res = master.execute(5, cst.READ_INPUT_REGISTERS, 1031, 73)
logger.info(res)
stats.parse_dynamic(res)
return stats
def gather_stats(mb, runtime):
now = localtime()
stats = poll_jh1600e_stats(master)
logger.info(stats)
if stats.read_groups != 3:
return
p_inst = float(stats.AC_power)
runtime.p_accm = runtime.p_accm + p_inst
runtime.p_count = runtime.p_count + 1
if p_inst > runtime.p_max:
runtime.p_max = p_inst
runtime.p_max_time = now
# every 10 minutes
if (now.tm_min % 10 == 0) & (stats.status == 'On') & (int(stats.offline_count)<2000):
if runtime.status_sent == False:
t_date = 'd={0}'.format(strftime('%Y%m%d'))
t_time = 't={0}'.format(strftime('%H:%M'))
t_energy = 'v1={0}'.format(stats.today_Wh)
#t_power = 'v2={0}'.format(runtime.p_accm/runtime.p_count)
t_power = 'v2={0}'.format(p_inst)
cmd = ['/usr/bin/curl',
'-d', t_date,
'-d', t_time,
'-d', t_energy,
'-d', t_power,
'-H', 'X-Pvoutput-Apikey: ' + PVOUTPUT_APIKEY,
'-H', 'X-Pvoutput-SystemId: ' + PVOUTPUT_SYSTEMID,
'http://pvoutput.org/service/r1/addstatus.jsp']
#logger.info(cmd)
l = 'NOW: p_inst = {0}W, p_avg = {1:.1f}W, e_total = {2}Wh, p_max {3}'.format(p_inst, runtime.p_accm/runtime.p_count, stats.today_Wh, runtime.p_max)
syslog.syslog(syslog.LOG_INFO, l)
ret = subprocess.call (cmd)
runtime.p_accm = 0
runtime.p_count = 0
runtime.status_sent = True
else:
runtime.status_sent = False
if (int(stats.offline_count) > 2000) & (stats.status == 'Off'):
if runtime.output_sent == False:
if runtime.p_max != 0:
data = 'data={0},{1},{2},{3},{4}'.format(strftime('%Y%m%d'),
stats.today_Wh, stats.today_Wh,
runtime.p_max, strftime('%H:%M', runtime.p_max_time))
cmd = ['/usr/bin/curl',
'-d', data,
'-H', 'X-Pvoutput-Apikey: ' + PVOUTPUT_APIKEY,
'-H', 'X-Pvoutput-SystemId: ' + PVOUTPUT_SYSTEMID,
'-H','X-Pvoutput-SystemId: 297',
'http://pvoutput.org/service/r1/addoutput.jsp']
#logger.info(cmd)
ret = subprocess.call (cmd)
l = 'EOD: e_total = {0}Wh, p_max = {1}W @ {2}'.format(stats.today_Wh, runtime.p_max, strftime('%H:%M', runtime.p_max_time))
syslog.syslog(syslog.LOG_INFO, l)
runtime.p_max = 0
runtime.output_sent = True
if stats.status == 'On':
runtime.output_sent = False
if __name__ == "__main__":
if RS485_PORT == '':
print 'RS-485 port not configured\nYou can set this by editing elogger_config.py'
exit()
runtime = logger_runtime()
syslog.openlog('energy_logger', 0, syslog.LOG_USER)
syslog.syslog(syslog.LOG_NOTICE, 'Started')
while True:
try:
# Connect to the slave
master = modbus_rtu.RtuMaster(serial.Serial(port=RS485_PORT, baudrate=9600, bytesize=8, parity='N', stopbits=1, xonxoff=0))
master.set_timeout(5.0)
master.set_verbose(True)
logger.info("connected")
runtime.p_accm = 0
runtime.p_count = 0
while True:
now = localtime()
# Every 10 Seconds
if now.tm_sec % 10 == 0:
gather_stats(master, runtime)
time.sleep(0.5)
# Get historical data
#res = master.execute(5, cst.READ_INPUT_REGISTERS, 2047, 28)
#logger.info(res)
#stats.parse_history(res)
#logger.info(master.execute(5, cst.READ_COILS, 24611, 1))
#logger.info(master.execute(5, cst.READ_COILS, 24616, 1))
except modbus_tk.modbus.ModbusError as e:
logger.error("%s- Code=%d" % (e, e.get_exception_code()))
except modbus_tk.modbus.ModbusInvalidResponseError :
pass
syslog.closelog()
syslog.syslog(syslog.LOG_NOTICE, 'Exiting')