diff --git a/ebusd-2.1.x/de/vaillant/15.vai00.csv b/ebusd-2.1.x/de/vaillant/15.vai00.csv new file mode 100644 index 00000000..843dc82e --- /dev/null +++ b/ebusd-2.1.x/de/vaillant/15.vai00.csv @@ -0,0 +1,18 @@ +# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275 Fernbedienung,,,,,,,,,,, +*r,,,,,,B509,0D,,,,,, +*w,,,,,,B509,0E,,,,,, +r9;w,,Lueftungsstufe,Lüftungsstufe,,,,2400,,,UCH,1=Tag;2=Aus;3=Auto;5=Nacht,, +r;w,,Lueftung_HI,Lüftung_HI,,,,5800,,,HCD:2,,, +# Writing works but seems to have no effect, might be pass through to RecoVair itself +r9;w,,Kuehlung,Kühlung - Sommer Bypass,,,,0a00,,,UCH,1=AUS;2=EIN,,,, +r9;w,,Kuehlung_Tage,Kühlung Tage,,,,3600,,,UCH,,,,, +r,,Uhrzeit,Uhrzeit,,,,2C00,,,VTI,,, +r;w,,Luftvolumen_High,Luftvolume in m3/h in Hi mode (HIGH),,,,4a00,,,UIN,,m3/h, +r;w,,Luftvolumen_minimum_Cool,Minimum Luftvolume in m3/h mit offenem Bypass (AIR5),,,,4800,,,UIN,,m3/h, +# not low something else +r;w,,Luftvolumen_Ferien,Luftvolume in m3/h im Ferien modus (AIR4),,,,4900,,,UIN,,m3/h, +r;w,,Luftvolumen_Nacht,Luftvolume in m3/h im Nacht modus (AIR1),,,,1800,,,UIN,,m3/h, +r;w,,Luftvolumen_Tag,Luftvolume in m3/h im Tag modus (AIR2),,,,1700,,,UIN,,m3/h, +r;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,kW/h, +r;w,,Alarm_Filter_FILT,Zeitraum zwischen 2 Alarmmeldungen fuer Filtertausch,,,,4500,,,UIN,,, diff --git a/ebusd-2.1.x/de/vaillant/c0.wtw04.csv b/ebusd-2.1.x/de/vaillant/c0.wtw04.csv new file mode 100644 index 00000000..cfc4e5a5 --- /dev/null +++ b/ebusd-2.1.x/de/vaillant/c0.wtw04.csv @@ -0,0 +1,31 @@ +# type (r[1-9] w u ),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275,,,,,,,,,,, +############ Luftvolumen################,,,,,,,,,,,,, +*r,,,,,c0,B509,0D,,,,,, +*w,,,,,c0,B509,0E,,,,,, +r;w,,Lueftungsvolumen,Lueftung m³/h,,,,1500,,,UIN,166=50;183=55;200=60;216=65;233=70;250=75;266=80;283=85;300=90;316=95;333=100;350=105;366=110;383=115;400=120;416=125;433=130;450=135;466=140;483=145;500=150;516=155;533=160;550=165;566=170;583=175;600=180;616=185;633=190;650=195;666=200;683=205;700=210;716=215;733=220;750=225;766=230;783=235;800=240;816=245;833=250;850=255;866=260;883=265;900=270,m³/h, +r;w,,SollVolumenstromkorrektur,Soll-Volumenstromkorrektur,,,,2000,,,D1B,,, +r9;w,,Kuehlung,Sommer bypass,,,,0a00,,,UCH,1=AUS;2=EIN,, +r;w,,Lueftung_HI,Lüftung_HI,,,,5800,,,HCD:2,,, +#29 seems to ask for info/status information +*r,,,,,c0,B509,29,,,IGN:2,,,first 2 bytes in response are the ID field again +r9,,BypassStellung,BypassStellung,,,,0900,,,percent0,,, +r1,,TempInletAir_SAI,Temperatur Aussenluft,,,,0100,,,temp,,°C, +r1,,TempOutsideAir_SAO,Temperatur Zuluft (Bypass),,,,0200,,,temp,,°C, +r1,,TempWasteAir_EAI,Temperatur Abluft,,,,0300,,,temp,,°C, +r1,,TempOutgoingAir_EAO,Temperatur Fortluft,,,,0400,,,temp,,°C, +# This is either wrong or room temp correction is missing +r1;w,,Roomtemp,Zimmertemperatur,,,,0000,,,temp;sensor,,°C, +#r1;w,,RoomTempOffset,Raumisttemp. Korrekturwert,,,,"1F00",,,temp,,, +#r1,,RoomTempOffsetSelfWarming,Offset Eigenerwärmung,,,,"2000",,,temp,,, +# other things +r;w,,Unterdruckschutz,Unterdruckschutz,,,,4700,,,UCH,1=AN;0=AUS,, +r;w,,Filter,Filter Tage,,,,4600,,,HCD:2,,, +#r;w,,UNKOWN_2,,,,,4300,,,,,,2 bytes +#r9;w,,UNKOWN_3,,,,,0e00,,,,,,1 byte, seems an on off, very often +#r9;w,,UNKOWN_3,,,,,0f00,,,,,,1 byte, seems an on off, very often +#r5;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,kW/h, +,,,,,,,,,,,,, +########### not working #################,,,,,,,,,,,,, +#r5;w,,Heatrecovery,Wärmerückgewinnung,,,,8c03,,,UCH,0=auto;1=on;2=off,,Aktuelle Uhrzeit +#r;w,,Desiredtemp,Wunschtemp,,,,140e,,,temp,,°C, diff --git a/ebusd-2.1.x/en/vaillant/15.vai00.csv b/ebusd-2.1.x/en/vaillant/15.vai00.csv new file mode 100644 index 00000000..139516fd --- /dev/null +++ b/ebusd-2.1.x/en/vaillant/15.vai00.csv @@ -0,0 +1,12 @@ +# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275 remote control,,,,,,,,,,, +*r,,,,,,B509,0D,,,,,, +*w,,,,,,B509,0E,,,,,, +#*wi,#install,,,,,B509,0F,,,,,, +# ##### general #####,,,,,,,,,,,,, +r9;w,,VentMode,,,,,2400,,,UCH,1=Day;2=Off;3=Auto;5=Night,, +r;w,,VentHI,Ventilation High time,,,,5800,,,HCD:2,,, +#Writing works but seems to have no effect, might be pass through to RecoVair itself +r9;w,,Cooling,Cooling - Summer Bypass,,,,0a00,,,UCH,1=Off;2=On,,,, +r9;w,,Cooling_days,Days that the cooling is enabled,,,,3600,,,UCH,,,,, +r,,Time,,,,,2C00,,,VTI,,, diff --git a/ebusd-2.1.x/en/vaillant/c0.wtw04.csv b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv new file mode 100644 index 00000000..2ee07508 --- /dev/null +++ b/ebusd-2.1.x/en/vaillant/c0.wtw04.csv @@ -0,0 +1,28 @@ +# type (r[1-9] w u ),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment +#,recov,RecoVair 275,,,,,,,,,,, +# ########### general ################,,,,,,,,,,,,, +*r,,,,,,B509,0D,,,,,, +*w,,,,,,B509,0E,,,,,, +r;w,,ventilation,ventilation level,,,,1500,,,UIN,166=50;183=55;200=60;216=65;233=70;250=75;266=80;283=85;300=90;316=95;333=100;350=105;366=110;383=115;400=120;416=125;433=130;450=135;466=140;483=145;500=150;516=155;533=160;550=165;566=170;583=175;600=180;616=185;633=190;650=195;666=200;683=205;700=210;716=215;733=220;750=225;766=230;783=235;800=240;816=245;833=250;850=255;866=260;883=265;900=270,m³/h, wartosc do wymnozenia przez 3/10 +r;w,,FlowCorrection,Set volume flow correction,,,,2000,,,D1B,,, +r9;w,,Cooling,Cooling - Summer Bypass,,,,0a00,,,UCH,1=Off;2=On,,,, +r;w,,VentHI,Ventilation High time,,,,5800,,,HCD:2,,, +#29 seems to ask for info/status information +*r,,,,,c0,B509,29,,,IGN:2,,,first 2 bytes in response are the ID field again +r9,,BypassValye,Bypass Position,,,,0900,,,percent0,,, +r1,,TempInletAir_SAI,Temperatur Aussenluft,,,,0100,,,temp,,°C, +r1,,TempOutsideAir_SAO,Temperatur Zuluft (Bypass),,,,0200,,,temp,,°C, +r1,,TempWasteAir_EAI,Temperatur Abluft,,,,0300,,,temp,,°C, +r1,,TempOutgoingAir_EAO,Temperatur Fortluft,,,,0400,,,temp,,°C, +# This is either wrong or room temp correction is missing +r1;w,,room_temperature,Room Temperature,,,,0000,,,temp;sensor,,°C, +#r1;w,,RoomTempOffset,Raumisttemp. Korrekturwert,,,,"1F00",,,temp,,, +#r1,,RoomTempOffsetSelfWarming,Offset Eigenerwärmung,,,,"2000",,,temp,,, +# Mike Kopp thinks this is "Unterdruckschutz +r;w,,FrostProtection,,,,,4700,,,onoff,,, +r;w,,Filter,Filter Days,,,,4600,,,HCD:2,,, +#r;w,,UNKOWN_2,,,,,4300,,,,,,2 bytes +#r9;w,,UNKOWN_3,,,,,0e00,,,,,,1 byte, seems an on off, very often +#r9;w,,UNKOWN_3,,,,,0f00,,,,,,1 byte, seems an on off, very often +#r5;w,,Ertrag_Gesamt_kWh,Ertrag_Gesamt_kWh,,,,4d00,,,UIN,,kW/h, +