ZCL8

BallastConfiguration.xml

  • CCB 2700: PICS code changed to BC
  • CCB 2881: Correction to spec text, no XML change needed
  • Updated cluster revision number

BarrierControl.xml

  • Not a new XML file, but this cluster appears for the first time in the ZCL specification as of ZCL8
  • Editorial: For BarrierPosition attribute, add default value 255 (i.e. 0xFF which signifies position is unknown)
  • No change to cluster revision number, remains at revision 1

Basic.xml

  • CCB 2722: changed the ZCLVersion attribute value to reflect the library release number, ie. 8
  • CCB 2885: Fixed the cluster revision error
  • CCB 3469: Updated second Office and Living Room entries to be "Secondary"

Calendar.xml

  • NEW

ColorControl.xml

  • CCB 2501: Correction to spec text, no XML change needed
  • CCB 2814: Added default values to OptionsMask and OptionsOverride fields in MoveToHue, MoveHue, StepHue, MoveToSaturation, MoveSaturation, StepSaturation, MoveToHueAndSaturation, MoveToColor, MoveColor, StepColor, MoveToColorTemperature, EnhancedMoveToHue, EnhancedMoveHue, EnhancedStepHue, EnhancedMoveToHueAndSaturation, ColorLoopSet, StopMoveStep, MoveColorTemperature, and StepColorTemperature
  • CCB 2839: Correction to spec text, no XML change needed
  • CCB 2840: Correction to spec text, no XML change needed
  • CCB 2843: Correction to spec text, no XML change needed
  • CCB 2861: Correction to spec text, no XML change needed
  • Updated cluster revision number

Commissioning.xml

  • CCB 2477: Clarification to spec text, no XML change needed.
  • CCB 2862: Clarification to spec text, no XML change needed.
  • CCB 2870: Editorial in spec which was not in XML due to number formatting.
  • Updated cluster revision number

ConcentrationMeasurement.xml

  • CCB 2882: The editorial correction to Cluster ID for Fluoride was already reflected in this XML
  • Add missing defaults for single-precision Value, Min and Max, set to NaN as specified in ZCL8
  • Added Cluster Identifiers (aliases) for PM1, PM10, and VolatileOrganicCompounds per 19-52988-001
  • Updated cluster revision number

DemandResponseAndLoadControl.xml

DeviceManagement.xml

  • NEW

DeviceTemperatureConfiguration.xml

  • Default values were updated to non on several clusters, no CCB reference in spec.
  • No update to the cluster revision in ZCL document.

Diagnostics.xml

  • CCB 2425: Duplicate of 2520
  • CCB 2520: Correction to spec text, no XML change needed
  • CCB 2521: Correction to spec text, no XML change needed
  • Updated cluster revision number

DoorLock.xml

  • Updated cluster revision number
  • Fixed the restriction statement for attribute NumberOfTotalUsersSupported
  • CCBs 2629 and 2630 made clarifications to ZCL8 specification text; no XML changes needed
  • Minor editorial changes to comments

ElectricalMeasurement.xml

  • CCB 2369: Textual clarification in ZCL8 spec, no XML change needed.
  • CCB 2817: Specified change already correctly reflected, no XML change needed.
  • Updated cluster revision number

EN50523ApplianceEventsAndAlerts.xml

  • XML validated against cluster specification.
  • Updated Cluster Revision

EN50523ApplianceStatistics.xml

  • XML validated against cluster specificiation.
  • Updated Cluster Revision

Events.xml

  • NEW

Groups.xml

  • CCB 2310: Cleanup of group id limits to be 0x0001 - 0xfff7
  • CCB 2704: Clarification of allowable status codes.
  • Updated cluster revision number

Identify.xml

  • CCB 2808: changed the data types of the Effect Identifier and Effect Variant fields in the Trigger Effect Command to enum8
  • Updated cluster revision number

KeepAlive.xml

  • NEW

KeyEstablishment.xml

  • NEW

Level.xml

  • CCB 2574: Changed the type of DefaultMoveRate to uint8.
  • CCB 2616: Clarification to spec text, no XML change needed.
  • CCB 2659: Clarification to spec text, no XML change needed.
  • CCB 2702: Clarification to spec text, no XML change needed.
  • CCB 2814: Added default values for OptionsMask and OptionsOverride fields.
  • CCB 2818: Clarification to spec text, no XML change needed.
  • CCB 2819: Clarification to spec text, no XML change needed.
  • CCB 2898: Clarification to spec text, no XML change needed.
  • Updated cluster revision number.

LevelControlForLighting.xml

MeterIdentification.xml

  • Validated scraped XML.
  • Updated cluster revision number

Metering.xml

  • NEW

OTAUpgrade.xml

  • CCB 2477: Clarification to spec text, no XML change needed.
  • CCB 2519: Clarification to spec text, no XML change needed.
  • CCB 2873: Clarification to spec text, no XML change needed.
  • Updated cluster revision number

OnOffSwitchConfiguration.xml

  • NEW

PollControl.xml

  • CCB 3285: swapped the command sides to match what's in the ZCL document. This was a scraping issue which was missed during initial review.
  • Updated cluster revision number

PowerConfiguration.xml

  • Updated the default values based on the changes in the ZCL
  • CCB 2454: Updated the BatteryAlarmState1, BatteryAlarmState2, and BatteryAlarmState3 attributes to be reportable.
  • Updated cluster revision number

Prepayment.xml

  • NEW

Price.xml

PulseWidthModulation.xml

Scenes.xml

  • CCB 2427: Clarification to spec text, no XML change needed.
  • CCB 3026: Change already reflected in XML, no further XML change needed.
  • Updated cluster revision number

SmartEnergyMessaging.xml

SmartEnergyTunneling.xml

SubGhz.xml

  • NEW

TemperatureMeasurement.xml

  • CCB 2823: corrects inconsistency in spec between attribute table and text for default value of int16; already correct in XML based on text, no change needed
  • Updated cluster revision number

Thermostat.xml

  • CCB 2477: Clarification to spec text, no XML change needed.
  • CCB 2560: Updated default value of occupancy to indicate occupied.
  • CCB 2773: Updated HVACSystemTypeConfiguration to R*W
  • CCB 2777: Updated MinSetpointDeadBand to R*W and changed min range to 0
  • CCB 2815: Added 00 = Unknown enumeration value to ACType, ACCapacity, ACRefrigerantType and ACCompressorType attributes
  • CCB 2816: Clarification to spec text, no XML change needed.
  • CCB 3029: Clarification to spec text, no XML change needed.
  • Fixing missed defaults and scene requirements
  • Updated cluster revision number

Time.xml

  • CCB 2544: Update the Time and TimeStatus attributes to be R*W from RW
  • CCB 2983: A partial update the spec indicating READ_ONLY status in case where writableIf doesn't match.

TouchlinkCommissioning.xml

  • CCB 2648: Clarification to spec text, no XML change needed.
  • Updated cluster revision number.

type.xsd

  • added default and defaultRef for command fields.

WindowCovering.xml

  • CCB 2555: Update the default value for CurrentPositionLiftPercentage and CurrentPositionTiltPercentage
  • Updated cluster revision number