title | description | addedAt | pageClass |
---|---|---|---|
Legrand 067776A control via MQTT |
Integrate your Legrand 067776A via Zigbee2MQTT with whatever smart home infrastructure you are using without the vendor's bridge or gateway. |
2023-10-03 20:27:32 UTC |
device-page |
Model | 067776A |
Vendor | Legrand |
Description | Netatmo wired shutter switch with level control (NLLV) |
Exposes | cover (state, position), action, identify, led_in_dark, led_if_on, calibration_mode, linkquality |
Picture |
You can calibrate your device (to enable position support) by closing the shutter (or opening it if your cover position is inverted) and pressing both the up and down buttons for about 5 seconds until you see a blinking yellow light. The shutter will begin calibrating itself and will open and close a few times (this process takes a few minutes to complete). To initiate calibrate using Z2M (rather than the buttons), perform the following steps:
- Ensure that the device is fully joined to the Z2M coordinator (green light solid, not flashing)
- Use the device's 'Exposes' page in Z2M to set the calibration mode (typically 'specific_nllv'). If it is already in the desired calibration mode, switch to a different calibration mode, wait a few seconds, then switch back.
- The LED should start flashing orange. Nothing will happen immediately - this is OK. Wait a few minutes, then the device will automatically lower the cover, wait a few minutes, then raise it again (or maybe do some other calibration steps depending upon your setup)
- The LED will stop flashing orange once calibration is complete (might take up to 5 minutes total)
Model number depends on the country and the colour of the devices. French models are branded as Céliane with Netatmo, and models for this device depends on the colour, with the following numbers: "0 677 26A", "0 677 76A" and "0 648 96A". Spanish models are branded as Legrand Valena Next, and models for this device depends on the colour, with the following numbers: "7 418 07A", "7 418 37A" and "7 418 67A".
There is a variant of this device that is an internal module (i.e. not a switch) with model "0 676 97". It only has two buttons (one for 'setup', the other that will toggle between raising and lowering the cover while that button is held down). Because it does not have separate up and down buttons, it is unknown how to force a calibration on this device (however see the calibration section above for details on how to calibrate using Z2M).
This device supports OTA updates, for more information see OTA updates.
How to use device type specific configuration
-
invert_cover
: Inverts the cover position, false: open=100,close=0, true: open=0,close=100 (default false). The value must betrue
orfalse
-
cover_position_tilt_disable_report
: Do not publish set cover target position as a normal 'position' value (default false). The value must betrue
orfalse
-
identity_effect
: Defines the identification effect to simplify the device identification. Example:
identity_effect:
effect: blink 3 # allowed: 'blink 3', 'fixed', 'blink green', 'blink blue'
color: red # allowed: 'default', 'red', 'green', 'blue', 'lightblue', 'yellow', 'pink', 'white'
The current state of this cover is in the published state under the state
property (value is OPEN
or CLOSE
).
To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "OPEN"}
, {"state": "CLOSE"}
, {"state": "STOP"}
.
It's not possible to read (/get
) this value.
To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"position": VALUE}
where VALUE
is a number between 0
and 100
.
Triggered action (e.g. a button click).
Value can be found in the published state on the action
property.
It's not possible to read (/get
) or write (/set
) this value.
The possible values are: identify
, open
, close
, stop
, moving
, stopped
.
Blinks the built-in LED to make it easier to identify the device.
Value will not be published in the state.
It's not possible to read (/get
) this value.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"identify": NEW_VALUE}
.
The possible values are: identify
.
Enables the built-in LED allowing to see the switch in the dark.
Value can be found in the published state on the led_in_dark
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"led_in_dark": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"led_in_dark": NEW_VALUE}
.
If value equals ON
led in dark is ON, if OFF
OFF.
Enables the LED on activity.
Value can be found in the published state on the led_if_on
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"led_if_on": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"led_if_on": NEW_VALUE}
.
If value equals ON
led if on is ON, if OFF
OFF.
Defines the calibration mode of the switch. (Caution: Changing modes requires a recalibration of the shutter switch!).
Value can be found in the published state on the calibration_mode
property.
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"calibration_mode": ""}
.
To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"calibration_mode": NEW_VALUE}
.
The possible values are: classic_nllv
, specific_nllv
, up_down_stop
, temporal
, venetian_bso
.
Link quality (signal strength).
Value can be found in the published state on the linkquality
property.
It's not possible to read (/get
) or write (/set
) this value.
The minimal value is 0
and the maximum value is 255
.
The unit of this value is lqi
.