Dk-core version 3.7.0 includes the following changes from 3.6.0:
- Added a new
DkCoreDiagnosticReportprofile for diagnostic reports (laboratory reports, personal health monitoring reports, and progress notes), with acategorysliced intostudyType,specialty, and a Danish-specificdanishSpecialty, an extensiblecodebinding, DK-Core-typed references, and worked examples (ElseHomeNursingMeasurements,ElseLaboratoryReport). - Added supporting terminology: value sets
dk-core-LoincDiagnosticDocumentTypes,dk-core-LoincLabStudyTypes,dk-core-SCTLaboratorySpecialities, anddk-core-practice-setting-exclude-lab-code. - Added a
cvrNamingSystem (Central Business Register,http://cvr.dk/ OID1.3.184) and a laboratoryDkCoreOrganizationexample (KliniskBiokemiHBY). - Upgraded the Personal Health Device (PHD) dependency to
hl7.fhir.uv.phd2.0.0 and migrated the Continua/PHD examples accordingly:phd-observationcategory code changed tophd, Continua code-system URLs re-pointed, gateway/coincident-timestamp linkage moved to theCoincidentTimeStampReferenceextension, added devicespecializationand certified-device-list properties, and blood-pressure status now usesvalueBoolean. - Updated dependencies:
hl7.fhir.uv.extensions.r4to the released 5.3.0, removedhl7.fhir.extensions.r54.0.1, and addedhl7.fhir.uv.xver-r5.r40.1.0. - Removed the local
dk-core-regional-subdivision-codesCodeSystem (and its alias); regional subdivisions now rely solely on ISO 3166-2. - Renamed FSH definitions to PascalCase while preserving canonical Ids (
V2_0131DkSupplement,ExtendedPatientContactRelationship) and updated theDkCorePatientcontact-relationship binding accordingly. - Added SNOMED CT copyright notices to the laboratory and SOR practice-setting value sets.
- Corrected SNOMED CT display names in examples to official Danish designations (e.g. "Cardiac pacemaker in situ" → "kardiel pacemaker in situ").