ERCP Basic

Table of contents

Version

This document describes ERCP Basic 0.1.0.

Generalities

ERCP Basic is the first protocol from the ERCP suite. It aims to provide simple and easy-to-implement yet reliable communication with embedded systems.

Frame format

General description

  • The frame reads top to bottom
  • Each cell represents an octet
  • Quoted values are ASCII characters
|---------|--
|   'E'   |  |
|---------|  |
|   'R'   |  |
|---------|  |
|   'C'   |  |- Start sequence
|---------|  |
|   'P'   |  |
|---------|  |
|   'B'   |  |
|---------|--
|   Type  |  |
|---------|  |- Header
|  Length |  |
|---------|--
|         |  |
    ...      |
|         |  |
|  Value  |  |- Payload
|         |  |
    ...      |
|         |  |
|---------|--
|   CRC   |  |
|---------|  |- Footer
|  'EOT'  |  |
|---------|--

Fields

  • Type: The command type. Several commands are built-in and the protocol is made to be extended by application commands handled by user callbacks.
  • Length: The length of the Value field.
  • Value: A field containing additional data.
  • CRC: CRC for the Type, Length and Value fiels combined.

Specification

A frame MUST start with a 5-byte start sequence composed, in order, by the E, R, C, P and B ASCII characters.

Immediately after the start sequence, a 2-byte header MUST be present. The first byte represents the Type field, while the second represents the Length field. The Type field MAY be any value. It SHOULD be a valid command type, understood by the receiving device. The Length field MUST be the length of the payload. It MAY be 0.

Immediately after the header, a payload MAY be present. It represents the Value field. If it is not present, the Length field MUST be 0. If it is present, its length MUST be equal to the Length field.

Immediately after the payload MUST follow a CRC. The CRC MUST be computed using the CRC-8-CCITT polynomial on the concatenation of the Type, Length and Value fields. The CRC calculation SHOULD be performed with a 256 lookup table for performance reasons. However, it MAY be computed directly if space is an issue.

Immediately after the CRC, the EOT ASCII character (0x04) MUST be present.

Behaviour on reception

A device receiving an incorrectly formatted frame MUST ignore it.

A device receiving a correctly formatted frame MUST compute its CRC. If the CRC is valid, the device MUST call the command callback corresponding to the Type. If the CRC is invalid or the command type is not implemented, the device MUST send a Nack(reason).

A device receiving an incomplete frame SHOULD start a timeout. If the implementation allows it, it SHOULD discard the frame after the timeout has been reached.

A device MAY set a maximum acceptable Length inferior to 255. In the case a too long frame is received, the device MUST send a Nack(TOO_LONG).

Built-in commands

Type Command
0x00 Ping()
0x01 Ack()
0x02 Nack(reason)
0x03 Reset()
0x04 Protocol()
0x05 Protocol_Reply(major, minor, patch)
0x06 Version(component)
0x07 Version_Reply(version)
0x08 Max_Length()
0x09 Max_Length_Reply()
0x0A-0x0F Reserved
0x10 Description()
0x11 Description_Reply(description)
0x12-0x1F Reserved
0xFF Log(message)

In the following subsections, commands are referred as functions taking zero or more arguments. Each command comes with a description, a type, a length and a value if appropriate. Then follows its expected behaviour.

All built-in commands MUST be implemented if not stated otherwise.

Reserved command types MUST NOT be used in application code.

Ping()

  • Description: Tests connectivity.
  • Type: 0x00
  • Length: 0

This command MAY be used to test connectivity.

A device receiving this command MUST reply with an Ack().

Ack()

  • Description: Acknowledgement.
  • Type: 0x01
  • Length: 0

This command SHOULD be sent to acknowledge a previously received command.

This command MAY be sent immediately after receiving the command or after doing some processing.

This command MUST NOT be sent if not replying to a command.

A device receiving this command MUST NOT reply.

Nack(reason)

  • Description: Negative acknowledgement.
  • Type: 0x02
  • Length: 1
  • Value:
    • reason on 8 bits

The following values for reason MUST be implemented:

  • 0x00: NO_REASON
  • 0x01: TOO_LONG
  • 0x02: INVALID_CRC
  • 0x03: UNKNOWN_COMMAND
  • 0x04: INVALID_ARGUMENTS

Values between 0x05 and 0x0F included are reserved for future use. They MUST NOT be used by application code.

Other values for reason MAY be implemented.

This command MUST be sent after a command with an invalid CRC has been received. In this case, reason MUST be INVALID_CRC.

This command MUST be sent after an unknown command has ben received. In this case, reason MUST be UNKNOWN_COMMAND.

This command SHOULD be sent to negatively acknowledge a previously received command. A custom reason MAY be used.

This command MAY be sent immediately after receiving the command or after doing some processing. In the second case, it SHOULD mean an problem has occured while processing the command.

This command MUST NOT be sent if not replying to a command.

A device receiving this command MUST NOT reply.

Reset()

  • Description: Resets the device.
  • Type: 0x03
  • Length: 0

This command MAY be used to reset the device.

A device receiving this command MAY permorm a reset.

If the expected behaviour is not implemented, a device receiving this command MUST send a Nack(UNKNOWN_COMMAND).

Protocol()

  • Description: Gets the protocol version.
  • Type: 0x04
  • Length: 0

This command SHOULD be used to check the protocol version implemented by the other end.

A device receiving this command MUST reply with a Protocol_Reply(major, minor, patch).

Protocol_Reply(major, minor, patch)

  • Description: Replies to Protocol().
  • Type: 0x05
  • Length: 3
  • Value:
    • major on 8 bits: the major version
    • minor on 8 bits: the minor version
    • patch on 8 bits: the patch version

This command MUST be sent after a Protocol() command has been received. Its value MUST state the version of the protocol implemented by the device.

This command MUST NOT be sent if not replying to Protocol().

A device receiving this command without waiting for it SHOULD reply with a Nack(UNKNOWN_COMMAND).

Version(component)

  • Description: Gets the version of a software component.
  • Type: 0x06
  • Length: 1
  • Value:
    • component on 8 bits

The following values for component SHOULD be implemented:

  • 0x00: Firmware Version
  • 0x01: ERCP Library Version

Values between 0x02 and 0x0F are reserved for future use. They MUST NOT be used by application code.

Other values for component MAY be implemented. Custom values MUST NOT replace the ones listed above.

This command MAY be used to get the version of a software component.

A device receiving this command MUST reply with a Version_Reply(version).

Version_Reply(version)

  • Description: Replies to Version(component).
  • Type: 0x07
  • Length: Variable
  • Value:
    • version on Length bytes: a UTF-8 string of characters. It SHOULD NOT be null-terminated.

This command MUST be sent after a Version(component) command has been received. If the component is unknown or not implemented, version SHOULD be "unknown_component". If the component is known, version:

  • MAY start with the name of the component if appropriate,
  • SHOULD end with the version of the component.

For instance, while the Firmware Version could be "1.0.0-rc.1", the ERCP Library Version could state its name, like in "ercp_rust 0.1.0", to contrast with "ercp_cpp 0.1.1".

This command MUST NOT be sent if not replying to Version(component).

A device receiving this command without waiting for it SHOULD reply with a Nack(UNKNOWN_COMMAND).

Max_Length()

  • Description: Gets the maximum acceptable Length.
  • Type: 0x08
  • Length: 0

This command SHOULD be used to get the maximum Length accepted by the other end.

A device receiving this command MUST reply with a Max_Length_Reply(max_length).

Max_Length_Reply(max_length)

  • Description: Replies to Max_Length().
  • Type: 0x09
  • Length: 1
  • Value:
    • max_length on 8 bits: the maximum acceptable length.

This command MUST be sent after a Max_Length() command has been received. max_length MUST be the maximum Length accepted by the device.

This command MUST NOT be sent if not replying to Max_Length().

A device receiving this command without waiting for it SHOULD reply with a Nack(UNKNOWN_COMMAND).

Description()

  • Description: Gets the device description.
  • Type: 0x10
  • Length: 0

This command MAY be used to get a description about the device. It MAY be used to get the correct set of useable application commands.

A device receiving this command MUST reply with a Description_Reply(description).

Description_Reply(description)

  • Description: Replies to Description().
  • Type: 0x11
  • Length: Variable
  • Value:
    • description on Length bytes: a UTF-8 string of characters. It SHOULD NOT be null-terminated.

This command MUST be sent after a Description() command has been received. description MAY be any valid string.

This command MUST NOT be sent if not replying to Description().

A device receiving this command without waiting for it SHOULD reply with a Nack(UNKNOWN_COMMAND).

Log(message)

  • Description: Logs a message.
  • Type: 0xFF
  • Length: Variable
  • Value:
    • message on Length bytes: a UTF-8 string of characters. It SHOULD NOT be null-terminated.

This command MAY be used to send logs.

A device receiving this command MUST reply with an Ack(). It MAY print message on a terminal or in a file.

Application commands

Application commands are commands defined by any application using ERCP Basic.

ERCP Basic implementations MUST provide a way to register application commands with a type and a callback.

An application command MUST have a type and a callback function or procedure.

An application command MUST NOT use the same type as a built-in command or any reserved value.

An application command MAY perform any action. On receiving the command or after a successful processing, an application command SHOULD send an Ack(). If there is a problem, it SHOULD send a Nack(reason). The reason SHOULD be a built-in value if appropriate and MAY be a custom value otherwise.

Component versions

The Version(component) command makes possible to get the version of an arbitrary component.

ERPC Basic implementations MUST provite a way to register components with their version.