Notifications
You must be signed in to change notification settings - Fork 3
/
Copy path3c..excellent.csv
We can make this file beautiful and searchable if this error is corrected: It looks like row 2 should actually have 15 columns, instead of 2 in line 1.
144 lines (144 loc) · 19.2 KB
/
3c..excellent.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
type,circuit,level,name,comment,qq,zz,pbsb,id,*name,part,type,divisor/values,unit,comment
*w,
*r,
w,,,FactoryReset,Rücksetzen auf Werkseinstellung,,,40ff,466163746f72795265736574,
w,,,ResetNotifications,Fehlerliste,,,4091,,value,,UIR,256=Errors;1=Filter;257=ErrorsAndFilter;0=NoResetRequested,,NoResetRequested is a dummy message doing nothing. It might be useful for integration in MQTT and HA automation. ErrorsAndFilter seems not working for me - but is specified.
r,,,RequestErrorList,Fehlerhistorie,,,4090,,value,,HEX:18,,,
w,,,SetFanMode,Ventilatorbetrieb,,,40a1,,value,,ULR,0=Holiday;65537=Reduced;131074=Normal;196611=High,,Temporary settings which resets after few minutes
w,,,SetFanModeAlt,VentilatorbetriebAlternative,,,40cb,0101,value,,UIR,0=Holiday;1=Reduced;2=Normal;3=High,,Does not reset after one minute with Sky300 with latest SW; this message is sent by Brink AirControl wall panel
r,,,FilterNotificationFlow,Maximaler Durchsatz Filter,,,4050,1c,volume,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³,
r,,,TotalFilterDays,Filterverwendung (Tage),,,4050,22,days,,UIR,,days,Tage,min,,UIR,,days,Tage,max,,UIR,,days,Tage,step,,UIR,,days,Tage,default,,UIR,,days,Tage
r,,,TotalFilterFlow,Filterverwendung,,,4050,23,volume,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³,
r,,,TotalOperatingHours,Betriebsdauer,,,4050,24,hours5,,UIR,-5,h,Stunden,min,,UIR,-5,h,Stunden,max,,UIR,-5,h,Stunden,step,,UIR,-5,h,Stunden,default,,UIR,-5,h,Stunden
r,,,TotalFlow,Gesamtdurchsatz,,,4050,25,volume,,UIR,-1000,m³,,min,,UIR,-1000,m³,,max,,UIR,-1000,m³,,step,,UIR,-1000,m³,,default,,UIR,-1000,m³,
r,,,FanMode,Ventilatorbetrieb,,,4022,01,value,,UIR,0=Holiday;1=Reduced;2=Normal;3=High;4=Auto,,
r,,,SettingInletFlow,Zuluftmenge,,,4022,09,value,,UIR,,m³/h,
r,,,SettingExhaustFlow,Abluftmenge,,,4022,0a,value,,UIR,,m³/h,
r,,,InletFlow,Tatsächliche Zuluftmenge,,,4022,0b,value,,UIR,,m³/h,
r,,,ExhaustFlow,Tatsächliche Abluftmenge,,,4022,0c,value,,UIR,,m³/h,
r,,,InletFanSpeed,Tatsächliche Drehzahl Zuluft,,,4022,02,value,,UIR,,rpm,
r,,,ExhaustFanSpeed,Tatsächliche Drehzahl Abluft,,,4022,03,value,,UIR,,rpm,
r,,,PerilexPosition,Position Perilexschalter,,,4022,05,value,,UIR,0=0;1=1;2=2;3=3,,
r,,,SwitchPosition,Position Stufenschalter,,,4022,06,value,,UIR,0=0;1=1;2=2;3=3,,
r,,,Contact1Position,Position Schalteingang 1,,,4022,1b,value,,UIR,0=off;1=on,,
r,,,Contact2Position,Position Schalteingang 2,,,4022,1c,value,,UIR,0=off;1=on,,
r,,,DipswitchValue,Wert DIP-Schalter,,,4022,04,value,,UIR,31=Excellent180Basic;30=Excellent180Plus;7=Excellent300Basic;6=Excellent300Plus;5=Excellent400Basic;4=Excellent400Plus;27=Excellent450Basic;26=Excellent450Plus;3=RenoventElan300Basic;2=RenoventElan300Plus;19=Sky150Basic;18=Sky150Plus;9=Sky200Basic;8=Sky200Plus;21=Sky300Basic;20=Sky300Plus,,
r,,,SoftwareVersion,Software Version,,,4022,00,value,,STR:13,,,
r,,,BypassStatus,Status Bypass,,,4022,0e,value,,UIR,0=Initializing;1=Opening;2=Closing;3=Open;4=Closed;5=Error;6=Calibrating;255=Error_1,,
r,,,BypassCurrent,Strom Bypass,,,4022,0d,value,,UIR,,,
r,,,PreheaterStatus,Status Vorheizregister,,,4022,0f,value,,UIR,0=Initializing;1=Off;2=On,,
r,,,PreheaterPower,Leistung Vorheizregister,,,4022,10,value,,UIR,,%,
r,,,PostheaterStatus,Status Nachheizregister,,,4022,1d,value,,UIR,0=Initializing;1=Off;2=On,,
r,,,PostheaterPower,Leistung Nachheizregister,,,4022,1e,value,,UIR,,%,
r,,,EWTStatus,Status Erdreichwärmetauscher,,,4022,1f,value,,UIR,0=OpenLow;1=Closed;2=OpenHigh,,
r,,,FrostStatus,Status Frostschutz,,,4022,16,value,,UIR,0=Initializing;1=NoFrost;17=NoFrost_1;2=DefrostWait;3=Preheater;18=Preheater_1;255=Error;5=VeluHeater;6=VeluFanCtrl;7=TableFanCtrl;19=TableFanCtrl_1;8=Sky150Heater;9=FanCtrlFanOff;10=FanCtrlFanRestart;11=FanCtrlCurve1;12=FanCtrlCurve2;13=FanCtrlCurve3;14=FanCtrlCurve4;15=HeaterCoolDown;16=Blocked,,
r,,,FanStatus,Status Ventilator,,,4022,11,value,,UIR,0=Initializing;1=ConstantFlow;2=ConstantPWM;3=Off;4=Error;5=MassBalance;6=Standby;7=ConstantRPM,,
r,,,InsideTemperature,Ablufttemperatur,,,4022,07,value,,SIR,10,°C,
r,,,OutsideTemperature,Außentemperatur,,,4022,08,value,,SIR,10,°C,
r,,,OptionTemperature,zusätzlicher Temperaturfühler,,,4022,1a,value,,SIR,10,°C,
r,,,FilterStatus,Filter verdreckt,,,4022,18,value,,UIR,0=no;1=yes,,
r,,,RelativeHumidity,relative Feuchte (RH-Sensor),,,4022,20,value,,SIR,10,%,
r,,,HumidityBoostState,Feuchtesensor Status,,,4022,21,value,,UIR,0=Error;1=NotInitialized;2=SensorNotActive;3=PowerUpDelay;4=NormalRH;5=BoostRising;6=BoostStable;7=BoostDecending;8=BoostRHLowLevelStable,Pa,
r,,,PressureInlet,Istwert Zuluftdruck,,,4022,14,value,,UIR,10,Pa,
r,,,PressureExhaust,Istwert Abluftdruck,,,4022,15,value,,UIR,10,Pa,
r,,,EBusSyncGenErrorCount,eBus Synch. Fehler,,,4022,64,value,,UIR,,,
r,,,CO2Sensor1Status,Status CO2-Sensor 1,,,4022,28,value,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,,
r,,,CO2Sensor1Value,Niveau CO2-Sensor 1,,,4022,29,value,,UIR,,ppm,
r,,,CO2Sensor2Status,Status CO2-Sensor 2,,,4022,2a,value,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,,
r,,,CO2Sensor2Value,Niveau CO2-Sensor 2,,,4022,2b,value,,UIR,,ppm,
r,,,CO2Sensor3Status,Status CO2-Sensor 3,,,4022,2c,value,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,,
r,,,CO2Sensor3Value,Niveau CO2-Sensor 3,,,4022,2d,value,,UIR,,ppm,
r,,,CO2Sensor4Status,Status CO2-Sensor 4,,,4022,2e,value,,UIR,0=Error;1=NotInitialized;2=Idle;3=WarmingUp;4=Running;5=Calibrating;6=SelfTest,,
r,,,CO2Sensor4Value,Niveau CO2-Sensor 4,,,4022,2f,value,,UIR,,ppm,
r,,,FlowMode0,Luftmenge Stufe 0,,,4050,21,speed,,UIR,,m³/h,,min,,UIR,,m³/h,[min:0],max,,UIR,,m³/h,[max:50],step,,UIR,,m³/h,[step:50],default,,UIR,,m³/h,[default:50]
w,,,FlowMode0,Luftmenge Stufe 0,,,4080,21,speed,,UIR,,m³/h,
r,,,FlowMode1,Luftmenge Stufe 1,,,4050,01,speed,,UIR,,m³/h,,min,,UIR,,m³/h,[min:50],max,,UIR,,m³/h,[max:300 or 400],step,,UIR,,m³/h,[step:5],default,,UIR,,m³/h,[default:100]
w,,,FlowMode1,Luftmenge Stufe 1,,,4080,01,speed,,UIR,,m³/h,
r,,,FlowMode2,Luftmenge Stufe 2,,,4050,02,speed,,UIR,,m³/h,,min,,UIR,,m³/h,[min:50],max,,UIR,,m³/h,[max:300 or 400],step,,UIR,,m³/h,[step:5],default,,UIR,,m³/h,[default:150 or 200]
w,,,FlowMode2,Luftmenge Stufe 2,,,4080,02,speed,,UIR,,m³/h,
r,,,FlowMode3,Luftmenge Stufe 3,,,4050,03,speed,,UIR,,m³/h,,min,,UIR,,m³/h,[min:50],max,,UIR,,m³/h,[max:300 or 400],step,,UIR,,m³/h,[step:5],default,,UIR,,m³/h,[default:225 or 300]
w,,,FlowMode3,Luftmenge Stufe 3,,,4080,03,speed,,UIR,,m³/h,
r,,,BypassTemp,Bypass Temperatur,,,4050,04,temp10,,SIR,10,°C,,min,,SIR,10,°C,[min:150],max,,SIR,10,°C,[max:350],step,,SIR,10,°C,[step:5],default,,SIR,10,°C,[default:240]
w,,,BypassTemp,Bypass Temperatur,,,4080,04,temp10,,SIR,10,°C,
r,,,BypassTempHyst,Bypass Hysterese,,,4050,30,temp10,,SIR,10,°C,,min,,SIR,10,°C,[min:0],max,,SIR,10,°C,[max:50],step,,SIR,10,°C,[step:5],default,,SIR,10,°C,[default:20]
w,,,BypassTempHyst,Bypass Hysterese,,,4080,30,temp10,,SIR,10,°C,
r,,,BypassMode,Bypassbetrieb,,,4050,1b,autocloseopen,,UIR,0=Auto;1=Closed;2=Open,,,ign,,IGN:6,,,,default,,UIR,0=Auto;1=Closed;2=Open,,[default:0] - min/max/step fields of enum message omitted
w,,,BypassMode,Bypassbetrieb,,,4080,1b,autocloseopen,,UIR,0=Auto;1=Closed;2=Open,,
r,,,CVWTWMode,Zentralheizung + WRG,,,4050,07,onoff,,UIR,0=off;1=on,,,ign,,IGN:6,,,,default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted
w,,,CVWTWMode,Zentralheizung + WRG,,,4080,07,onoff,,UIR,0=off;1=on,,
r,,,UnbalanceMode,Ungleichgewicht möglich,,,4050,08,yesno,,UIR,0=no;1=yes,,,ign,,IGN:6,,,,default,,UIR,0=no;1=yes,,[default:1] - min/max/step fields of enum message omitted
w,,,UnbalanceMode,Ungleichgewicht möglich,,,4080,08,yesno,,UIR,0=no;1=yes,,
r,,,UnbalanceFlow,Ständiges Ungleichgewicht,,,4050,09,speed,,SIR,,m³/h,,min,,SIR,,m³/h,[min:-100],max,,SIR,,m³/h,[max:100],step,,SIR,,m³/h,[step:1],default,,SIR,,m³/h,[default:0]
w,,,UnbalanceFlow,Ständiges Ungleichgewicht,,,4080,09,speed,,SIR,,m³/h,
r,,,ExtraHeaterType,Typ zusätsliches Heizregister,,,4050,0a,uir,,UIR,,,,min,,UIR,,,[min:0],max,,UIR,,,[max:2],step,,UIR,,,[step:1],default,,UIR,,,[default:0]
w,,,ExtraHeaterType,Typ zusätsliches Heizregister,,,4080,0a,uir,,UIR,,,
r,,,PostheaterTemp,Temperatur Nachheizregister,,,4050,0b,temp10,,SIR,10,°C,,min,,SIR,10,°C,[min:150],max,,SIR,10,°C,[max:300],step,,SIR,10,°C,[step:5],default,,SIR,10,°C,[default:210]
w,,,PostheaterTemp,Temperatur Nachheizregister,,,4080,0b,temp10,,SIR,10,°C,
r,,,Input1Mode,Auswahl Eingang 1,,,4050,0c,inputmode,,UIR,0=Normally_Closed;1=_0_10V_input;2=Normally_Open;3=_12V_Bypass_Open_0V_Bypass_Closed;4=_0V_Bypass_Open_12V_Bypass_Closed,,,ign,,IGN:6,,,,default,,UIR,0=Normally_Closed;1=_0_10V_input;2=Normally_Open;3=_12V_Bypass_Open_0V_Bypass_Closed;4=_0V_Bypass_Open_12V_Bypass_Closed,,[default:0] - min/max/step fields of enum message omitted
w,,,Input1Mode,Auswahl Eingang 1,,,4080,0c,inputmode,,UIR,0=Normally_Closed;1=_0_10V_input;2=Normally_Open;3=_12V_Bypass_Open_0V_Bypass_Closed;4=_0V_Bypass_Open_12V_Bypass_Closed,,
r,,,Input1VMin,Minimale Spannung Eingang 1,,,4050,0d,voltage,,SIR,10,V,,min,,SIR,10,V,[min:0],max,,SIR,10,V,[max:100],step,,SIR,10,V,[step:5],default,,SIR,10,V,[default:0]
w,,,Input1VMin,Minimale Spannung Eingang 1,,,4080,0d,voltage,,SIR,10,V,
r,,,Input1VMax,Maximale Spannung Eingang 1,,,4050,0e,voltage,,SIR,10,V,,min,,SIR,10,V,[min:0],max,,SIR,10,V,[max:100],step,,SIR,10,V,[step:5],default,,SIR,10,V,[default:100]
w,,,Input1VMax,Maximale Spannung Eingang 1,,,4080,0e,voltage,,SIR,10,V,
r,,,CN1Coupling,Bedingungen Schalteingang 1,,,4050,0f,onoffbypass,,UIR,0=off;1=on;2=on_if_bypass_open_condition_satisfied;3=bypass_control;4=Bedroom_valve,,,ign,,IGN:6,,,,default,,UIR,0=off;1=on;2=on_if_bypass_open_condition_satisfied;3=bypass_control;4=Bedroom_valve,,[default:0] - min/max/step fields of enum message omitted
w,,,CN1Coupling,Bedingungen Schalteingang 1,,,4080,0f,onoffbypass,,UIR,0=off;1=on;2=on_if_bypass_open_condition_satisfied;3=bypass_control;4=Bedroom_valve,,
r,,,CN1Inlet,Funktion Zuluftventilator Eingang 1,,,4050,10,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,ign,,IGN:6,,,,default,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted
w,,,CN1Inlet,Funktion Zuluftventilator Eingang 1,,,4080,10,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,
r,,,CN1Exhaust,Funktion Abluftventilator Eingang 1,,,4050,11,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,ign,,IGN:6,,,,default,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted
w,,,CN1Exhaust,Funktion Abluftventilator Eingang 1,,,4080,11,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,
r,,,Input2Mode,Auswahl Eingang 2,,,4050,12,inputmode,,UIR,0=Normally_Closed;1=_0_10V_input;2=Normally_Open;3=_12V_Bypass_Open_0V_Bypass_Closed;4=_0V_Bypass_Open_12V_Bypass_Closed,,,ign,,IGN:6,,,,default,,UIR,0=Normally_Closed;1=_0_10V_input;2=Normally_Open;3=_12V_Bypass_Open_0V_Bypass_Closed;4=_0V_Bypass_Open_12V_Bypass_Closed,,[default:1] - min/max/step fields of enum message omitted
w,,,Input2Mode,Auswahl Eingang 2,,,4080,12,inputmode,,UIR,0=Normally_Closed;1=_0_10V_input;2=Normally_Open;3=_12V_Bypass_Open_0V_Bypass_Closed;4=_0V_Bypass_Open_12V_Bypass_Closed,,
r,,,Input2VMin,Minimale Spannung Eingang 2,,,4050,13,voltage,,SIR,10,V,,min,,SIR,10,V,[min:0],max,,SIR,10,V,[max:100],step,,SIR,10,V,[step:5],default,,SIR,10,V,[default:0]
w,,,Input2VMin,Minimale Spannung Eingang 2,,,4080,13,voltage,,SIR,10,V,
r,,,Input2VMax,Maximale Spannung Eingang 2,,,4050,14,voltage,,SIR,10,V,,min,,SIR,10,V,[min:0],max,,SIR,10,V,[max:100],step,,SIR,10,V,[step:5],default,,SIR,10,V,[default:100]
w,,,Input2VMax,Maximale Spannung Eingang 2,,,4080,14,voltage,,SIR,10,V,
r,,,CN2Coupling,Bedingungen Schalteingang 2,,,4050,15,onoffbypass,,UIR,0=off;1=on;2=on_if_bypass_open_condition_satisfied;3=bypass_control;4=Bedroom_valve,,,ign,,IGN:6,,,,default,,UIR,0=off;1=on;2=on_if_bypass_open_condition_satisfied;3=bypass_control;4=Bedroom_valve,,[default:0] - min/max/step fields of enum message omitted
w,,,CN2Coupling,Bedingungen Schalteingang 2,,,4080,15,onoffbypass,,UIR,0=off;1=on;2=on_if_bypass_open_condition_satisfied;3=bypass_control;4=Bedroom_valve,,
r,,,CN2Inlet,Funktion Zuluftventilator Eingang 2,,,4050,16,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,ign,,IGN:6,,,,default,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted
w,,,CN2Inlet,Funktion Zuluftventilator Eingang 2,,,4080,16,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,
r,,,CN2Exhaust,Funktion Abluftventilator Eingang 2,,,4050,17,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,,ign,,IGN:6,,,,default,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,[default:5] - min/max/step fields of enum message omitted
w,,,CN2Exhaust,Funktion Abluftventilator Eingang 2,,,4080,17,fanmode,,UIR,0=FanOff;1=Minimal_flow_50m3_h;2=FanMode1;3=FanMode2;4=FanMode3;5=ManualSwitch;6=MaximalFlow;7=FanNotActive,,
r,,,EWTMode,Erdreichwärmetauscher,,,4050,18,onoff,,UIR,0=off;1=on,,,ign,,IGN:6,,,,default,,UIR,0=off;1=on,,[default:0] - min/max/step fields of enum message omitted
w,,,EWTMode,Erdreichwärmetauscher,,,4080,18,onoff,,UIR,0=off;1=on,,
r,,,EWTTempMin,Min. Temp. Erdreichwärmetauscher,,,4050,19,temp10,,SIR,10,°C,,min,,SIR,10,°C,[min:0],max,,SIR,10,°C,[max:100],step,,SIR,10,°C,[step:5],default,,SIR,10,°C,[default:50]
w,,,EWTTempMin,Min. Temp. Erdreichwärmetauscher,,,4080,19,temp10,,SIR,10,°C,
r,,,EWTTempMax,Max. Temp. Erdreichwärmetauscher,,,4050,1a,temp10,,SIR,10,°C,,min,,SIR,10,°C,[min:150],max,,SIR,10,°C,[max:400],step,,SIR,10,°C,[step:5],default,,SIR,10,°C,[default:250]
w,,,EWTTempMax,Max. Temp. Erdreichwärmetauscher,,,4080,1a,temp10,,SIR,10,°C,
r,,,RHTSensorPresent,Feuchtesensor vorhanden,,,4050,32,uir,,UIR,,,,min,,UIR,,,[min:0],max,,UIR,,,[max:1],step,,UIR,,,[step:1],default,,UIR,,,[default:0]
w,,,RHTSensorPresent,Feuchtesensor vorhanden,,,4080,32,uir,,UIR,,,
r,,,RHTSensorSensitivity,Empfindlichkeit Feuchtesensor,,,4050,33,sir,,SIR,,,,min,,SIR,,,[min:-2],max,,SIR,,,[max:2],step,,SIR,,,[step:1],default,,SIR,,,[default:0]
w,,,RHTSensorSensitivity,Empfindlichkeit Feuchtesensor,,,4080,33,sir,,SIR,,,
r,,,BacklightLevel,Beleuchtung Display,,,4050,1d,percentr,,UIR,,%,,min,,UIR,,%,[min:0],max,,UIR,,%,[max:100],step,,UIR,,%,[step:5],default,,UIR,,%,[default:10]
w,,,BacklightLevel,Beleuchtung Display,,,4080,1d,percentr,,UIR,,%,
r,,,CO2Sensor1LowerLimit,CO2-Sensor 1; unterer Grenzwert,,,4050,34,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:400]
w,,,CO2Sensor1LowerLimit,CO2-Sensor 1; unterer Grenzwert,,,4080,34,uir,,UIR,,ppm,
r,,,CO2Sensor1UpperLimit,CO2-Sensor 1; oberer Grenzwert,,,4050,35,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:1200]
w,,,CO2Sensor1UpperLimit,CO2-Sensor 1; oberer Grenzwert,,,4080,35,uir,,UIR,,ppm,
r,,,CO2Sensor2LowerLimit,CO2-Sensor 2; unterer Grenzwert,,,4050,36,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:400]
w,,,CO2Sensor2LowerLimit,CO2-Sensor 2; unterer Grenzwert,,,4080,36,uir,,UIR,,ppm,
r,,,CO2Sensor2UpperLimit,CO2-Sensor 2; oberer Grenzwert,,,4050,37,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:1200]
w,,,CO2Sensor2UpperLimit,CO2-Sensor 2; oberer Grenzwert,,,4080,37,uir,,UIR,,ppm,
r,,,CO2Sensor3LowerLimit,CO2-Sensor 3; unterer Grenzwert,,,4050,38,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:400]
w,,,CO2Sensor3LowerLimit,CO2-Sensor 3; unterer Grenzwert,,,4080,38,uir,,UIR,,ppm,
r,,,CO2Sensor3UpperLimit,CO2-Sensor 3; oberer Grenzwert,,,4050,39,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:1200]
w,,,CO2Sensor3UpperLimit,CO2-Sensor 3; oberer Grenzwert,,,4080,39,uir,,UIR,,ppm,
r,,,CO2Sensor4LowerLimit,CO2-Sensor 4; unterer Grenzwert,,,4050,3a,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:400]
w,,,CO2Sensor4LowerLimit,CO2-Sensor 4; unterer Grenzwert,,,4080,3a,uir,,UIR,,ppm,
r,,,CO2Sensor4UpperLimit,CO2-Sensor 4; oberer Grenzwert,,,4050,3b,uir,,UIR,,ppm,,min,,UIR,,ppm,[min:400],max,,UIR,,ppm,[max:2000],step,,UIR,,ppm,[step:25],default,,UIR,,ppm,[default:1200]
w,,,CO2Sensor4UpperLimit,CO2-Sensor 4; oberer Grenzwert,,,4080,3b,uir,,UIR,,ppm,
r,,,CO2SensorsActivated,CO2-Sensoren aktiviert,,,4050,3c,yesno,,UIR,0=no;1=yes,,,ign,,IGN:6,,,,default,,UIR,0=no;1=yes,,[default:0] - min/max/step fields of enum message omitted
w,,,CO2SensorsActivated,CO2-Sensoren aktiviert,,,4080,3c,yesno,,UIR,0=no;1=yes,,
r,,,FlowCorrection,Durchsatzkorrektur,,,4050,3f,percentr,,UIR,,%,,min,,UIR,,%,[min:90],max,,UIR,,%,[max:110],step,,UIR,,%,[step:1],default,,UIR,,%,[default:100]
w,,,FlowCorrection,Durchsatzkorrektur,,,4080,3f,percentr,,UIR,,%,
r,,,SwitchDefaultPos,Schaltergrundstellung,,,4050,40,onoff,,UIR,0=off;1=on,,,ign,,IGN:6,,,,default,,UIR,0=off;1=on,,[default:1] - min/max/step fields of enum message omitted
w,,,SwitchDefaultPos,Schaltergrundstellung,,,4080,40,onoff,,UIR,0=off;1=on,,
r,,,FilterDaysBeforeWarning,Tage vor Filterwarnung,,,4050,45,uir,,UIR,,,,min,,UIR,,,[min:1],max,,UIR,,,[max:365],step,,UIR,,,[step:1],default,,UIR,,,[default:90]
w,,,FilterDaysBeforeWarning,Tage vor Filterwarnung,,,4080,45,uir,,UIR,,,
r,,,ModbusInterface,Schnittstelle Modbus,,,4050,41,uir,,UIR,,,,min,,UIR,,,[min:0],max,,UIR,,,[max:3],step,,UIR,,,[step:2],default,,UIR,,,[default:1]
w,,,ModbusInterface,Schnittstelle Modbus,,,4080,41,uir,,UIR,,,
r,,,ModbusSlaveAddress,Adresse Modbus-Slave,,,4050,42,uir,,UIR,,,,min,,UIR,,,[min:1],max,,UIR,,,[max:247],step,,UIR,,,[step:1],default,,UIR,,,[default:11]
w,,,ModbusSlaveAddress,Adresse Modbus-Slave,,,4080,42,uir,,UIR,,,
r,,,ModbusSpeed,Geschwindigkeit Modbus,,,4050,43,baud,,UIR,0=_1k2;1=_2k4;2=_4k8;3=_9k6;4=_19k2;5=_38k4;6=_56k;7=_115k,baud,,ign,,IGN:6,,,,default,,UIR,0=_1k2;1=_2k4;2=_4k8;3=_9k6;4=_19k2;5=_38k4;6=_56k;7=_115k,baud,[default:3] - min/max/step fields of enum message omitted
w,,,ModbusSpeed,Geschwindigkeit Modbus,,,4080,43,baud,,UIR,0=_1k2;1=_2k4;2=_4k8;3=_9k6;4=_19k2;5=_38k4;6=_56k;7=_115k,baud,
r,,,ModbusParity,Parität Modbus,,,4050,44,parity,,UIR,0=None;1=Even;2=Odd;3=Unknown,,,ign,,IGN:6,,,,default,,UIR,0=None;1=Even;2=Odd;3=Unknown,,[default:1] - min/max/step fields of enum message omitted
w,,,ModbusParity,Parität Modbus,,,4080,44,parity,,UIR,0=None;1=Even;2=Odd;3=Unknown,,