-
Notifications
You must be signed in to change notification settings - Fork 124
/
Copy pathFRAME-RELAY-DTE-MIB-V1SMI.my
974 lines (888 loc) · 28.9 KB
/
FRAME-RELAY-DTE-MIB-V1SMI.my
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
-- MIB file created 01-Apr-2003 09:25:16, by
-- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com
FRAME-RELAY-DTE-MIB DEFINITIONS ::= BEGIN
-- From file: "FRAME-RELAY-DTE-MIB.my"
-- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T"
IMPORTS
RowStatus, TimeStamp
FROM SNMPv2-TC-v1
transmission
FROM RFC1213-MIB
InterfaceIndex
FROM IF-MIB
Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
frameRelayDTE OBJECT IDENTIFIER ::= { transmission 32 }
-- MODULE-IDENTITY
-- LastUpdated
-- 9705010229Z
-- OrgName
-- IETF IPLPDN Working Group
-- ContactInfo
-- Caralyn Brown
-- Postal: Cadia Networks, Inc.
-- 1 Corporate Drive
-- Andover, Massachusetts 01810
-- Tel: +1 508 689 2400 x133
-- E-Mail: [email protected]
--
-- Fred Baker
-- Postal: Cisco Systems
-- 519 Lado Drive
-- Santa Barbara, California 93111
-- Tel: +1 408 526 425
-- E-Mail: [email protected]
-- Descr
-- The MIB module to describe the use of a Frame Relay
-- interface by a DTE.
-- RevDate
-- 9705010229Z
-- RevDescr
-- Converted from SMIv1 to SMIv2. (Thus, indices are
-- read-only rather than being not-accessible.) Added
-- objects and made clarifications based on implementation
-- experience.
-- RevDate
-- 9204010000Z
-- RevDescr
-- Published as RFC 1315, the initial version of this MIB
-- module.
frameRelayTrapControl OBJECT IDENTIFIER ::= { frameRelayDTE 4 }
frameRelayTraps OBJECT IDENTIFIER ::= { frameRelayDTE 0 }
frConformance OBJECT IDENTIFIER ::= { frameRelayDTE 6 }
frGroups OBJECT IDENTIFIER ::= { frConformance 1 }
frCompliances OBJECT IDENTIFIER ::= { frConformance 2 }
DLCI ::= INTEGER(0..8388607)
-- TEXTUAL-CONVENTION
-- Status
-- mandatory
-- Descr
-- The range of DLCI values. Note that this varies by
-- interface configuration; normally, interfaces may use
-- 0..1023, but may be configured to use ranges as large
-- as 0..2^23.
frDlcmiTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrDlcmiEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Parameters for the Data Link Connection Management
Interface for the frame relay service on this
interface."
REFERENCE
"American National Standard T1.617-1991, Annex D"
::= { frameRelayDTE 1 }
frDlcmiEntry OBJECT-TYPE
SYNTAX FrDlcmiEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Parameters for a particular Data Link Connection
Management Interface."
INDEX { frDlcmiIfIndex }
::= { frDlcmiTable 1 }
FrDlcmiEntry ::= SEQUENCE {
frDlcmiIfIndex InterfaceIndex,
frDlcmiState INTEGER,
frDlcmiAddress INTEGER,
frDlcmiAddressLen INTEGER,
frDlcmiPollingInterval INTEGER,
frDlcmiFullEnquiryInterval INTEGER,
frDlcmiErrorThreshold INTEGER,
frDlcmiMonitoredEvents INTEGER,
frDlcmiMaxSupportedVCs DLCI,
frDlcmiMulticast INTEGER,
frDlcmiStatus INTEGER,
frDlcmiRowStatus RowStatus
}
frDlcmiIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
-- Rsyntax INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value of the corresponding ifEntry."
::= { frDlcmiEntry 1 }
frDlcmiState OBJECT-TYPE
SYNTAX INTEGER {
noLmiConfigured(1),
lmiRev1(2),
ansiT1617D(3),
ansiT1617B(4),
itut933A(5),
ansiT1617D1994(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable states which Data Link Connection
Management scheme is active (and by implication, what
DLCI it uses) on the Frame Relay interface."
REFERENCE
"American National Standard T1.617-1991, American
National Standard T1.617a-1994, ITU-T Recommendation
Q.933 (03/93)."
::= { frDlcmiEntry 2 }
frDlcmiAddress OBJECT-TYPE
SYNTAX INTEGER {
q921(1),
q922March90(2),
q922November90(3),
q922(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable states which address format is in use on
the Frame Relay interface."
::= { frDlcmiEntry 3 }
frDlcmiAddressLen OBJECT-TYPE
SYNTAX INTEGER {
twoOctets(2),
threeOctets(3),
fourOctets(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable states the address length in octets. In
the case of Q922 format, the length indicates the
entire length of the address including the control
portion."
::= { frDlcmiEntry 4 }
frDlcmiPollingInterval OBJECT-TYPE
SYNTAX INTEGER(5..30)
-- Units
-- seconds
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the number of seconds between successive
status enquiry messages."
REFERENCE
"American National Standard T1.617-1991, Section D.7
Timer T391."
DEFVAL { 10 }
::= { frDlcmiEntry 5 }
frDlcmiFullEnquiryInterval OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of status enquiry intervals that pass before
issuance of a full status enquiry message."
REFERENCE
"American National Standard T1.617-1991, Section D.7
Counter N391."
DEFVAL { 6 }
::= { frDlcmiEntry 6 }
frDlcmiErrorThreshold OBJECT-TYPE
SYNTAX INTEGER(1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the maximum number of unanswered Status
Enquiries the equipment shall accept before declaring
the interface down."
REFERENCE
"American National Standard T1.617-1991, Section D.5.1
Counter N392."
DEFVAL { 3 }
::= { frDlcmiEntry 7 }
frDlcmiMonitoredEvents OBJECT-TYPE
SYNTAX INTEGER(1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the number of status polling intervals over
which the error threshold is counted. For example, if
within 'MonitoredEvents' number of events the station
receives 'ErrorThreshold' number of errors, the
interface is marked as down."
REFERENCE
"American National Standard T1.617-1991, Section D.5.2
Counter N393."
DEFVAL { 4 }
::= { frDlcmiEntry 8 }
frDlcmiMaxSupportedVCs OBJECT-TYPE
SYNTAX DLCI
-- Rsyntax INTEGER(0..8388607)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum number of Virtual Circuits allowed for
this interface. Usually dictated by the Frame Relay
network.
In response to a SET, if a value less than zero or
higher than the agent's maximal capability is
configured, the agent should respond badValue"
::= { frDlcmiEntry 9 }
frDlcmiMulticast OBJECT-TYPE
SYNTAX INTEGER {
nonBroadcast(1),
broadcast(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates whether the Frame Relay interface is
using a multicast service."
::= { frDlcmiEntry 10 }
frDlcmiStatus OBJECT-TYPE
SYNTAX INTEGER {
running(1),
fault(2),
initializing(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates the status of the Frame Relay interface
as determined by the performance of the dlcmi. If no
dlcmi is running, the Frame Relay interface will stay
in the running state indefinitely."
::= { frDlcmiEntry 11 }
frDlcmiRowStatus OBJECT-TYPE
SYNTAX RowStatus
-- Rsyntax INTEGER {
-- active(1),
-- notInService(2),
-- notReady(3),
-- createAndGo(4),
-- createAndWait(5),
-- destroy(6)
-- }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP Version 2 Row Status Variable. Writable objects
in the table may be written in any RowStatus state."
::= { frDlcmiEntry 12 }
frCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing information about specific Data
Link Connections (DLC) or virtual circuits."
::= { frameRelayDTE 2 }
frCircuitEntry OBJECT-TYPE
SYNTAX FrCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The information regarding a single Data Link
Connection. Discontinuities in the counters contained
in this table are indicated by the value in
frCircuitCreationTime."
INDEX { frCircuitIfIndex, frCircuitDlci }
::= { frCircuitTable 1 }
FrCircuitEntry ::= SEQUENCE {
frCircuitIfIndex InterfaceIndex,
frCircuitDlci DLCI,
frCircuitState INTEGER,
frCircuitReceivedFECNs Counter,
frCircuitReceivedBECNs Counter,
frCircuitSentFrames Counter,
frCircuitSentOctets Counter,
frCircuitReceivedFrames Counter,
frCircuitReceivedOctets Counter,
frCircuitCreationTime TimeStamp,
frCircuitLastTimeChange TimeStamp,
frCircuitCommittedBurst INTEGER,
frCircuitExcessBurst INTEGER,
frCircuitThroughput INTEGER,
frCircuitMulticast INTEGER,
frCircuitType INTEGER,
frCircuitDiscards Counter,
frCircuitReceivedDEs Counter,
frCircuitSentDEs Counter,
frCircuitLogicalIfIndex InterfaceIndex,
frCircuitRowStatus RowStatus
}
frCircuitIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
-- Rsyntax INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex Value of the ifEntry this virtual circuit
is layered onto."
::= { frCircuitEntry 1 }
frCircuitDlci OBJECT-TYPE
SYNTAX DLCI
-- Rsyntax INTEGER(0..8388607)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Data Link Connection Identifier for this virtual
circuit."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.6"
::= { frCircuitEntry 2 }
frCircuitState OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
active(2),
inactive(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether the particular virtual circuit is
operational. In the absence of a Data Link Connection
Management Interface, virtual circuit entries (rows)
may be created by setting virtual circuit state to
'active', or deleted by changing Circuit state to
'invalid'.
Whether or not the row actually disappears is left to
the implementation, so this object may actually read as
'invalid' for some arbitrary length of time. It is
also legal to set the state of a virtual circuit to
'inactive' to temporarily disable a given circuit.
The use of 'invalid' is deprecated in this SNMP Version
2 MIB, in favor of frCircuitRowStatus."
DEFVAL { active }
::= { frCircuitEntry 3 }
frCircuitReceivedFECNs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received from the network indicating
forward congestion since the virtual circuit was
created. This occurs when the remote DTE sets the FECN
flag, or when a switch in the network enqueues the
frame to a trunk whose transmission queue is
congested."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.3"
::= { frCircuitEntry 4 }
frCircuitReceivedBECNs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received from the network indicating
backward congestion since the virtual circuit was
created. This occurs when the remote DTE sets the BECN
flag, or when a switch in the network receives the
frame from a trunk whose transmission queue is
congested."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.4"
::= { frCircuitEntry 5 }
frCircuitSentFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames sent from this virtual circuit
since it was created."
::= { frCircuitEntry 6 }
frCircuitSentOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets sent from this virtual circuit
since it was created. Octets counted are the full
frame relay header and the payload, but do not include
the flag characters or CRC."
::= { frCircuitEntry 7 }
frCircuitReceivedFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received over this virtual circuit
since it was created."
::= { frCircuitEntry 8 }
frCircuitReceivedOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets received over this virtual circuit
since it was created. Octets counted include the full
frame relay header, but do not include the flag
characters or the CRC."
::= { frCircuitEntry 9 }
frCircuitCreationTime OBJECT-TYPE
SYNTAX TimeStamp
-- Rsyntax TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the virtual circuit was
created, whether by the Data Link Connection Management
Interface or by a SetRequest."
::= { frCircuitEntry 10 }
frCircuitLastTimeChange OBJECT-TYPE
SYNTAX TimeStamp
-- Rsyntax TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when last there was a change in
the virtual circuit state"
::= { frCircuitEntry 11 }
frCircuitCommittedBurst OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates the maximum amount of data, in
bits, that the network agrees to transfer under normal
conditions, during the measurement interval."
REFERENCE
"American National Standard T1.617-1991, Section
6.5.19"
DEFVAL { 0 }
::= { frCircuitEntry 12 }
frCircuitExcessBurst OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates the maximum amount of
uncommitted data bits that the network will attempt to
deliver over the measurement interval.
By default, if not configured when creating the entry,
the Excess Information Burst Size is set to the value
of ifSpeed."
REFERENCE
"American National Standard T1.617-1991, Section
6.5.19"
::= { frCircuitEntry 13 }
frCircuitThroughput OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Throughput is the average number of 'Frame Relay
Information Field' bits transferred per second across a
user network interface in one direction, measured over
the measurement interval.
If the configured committed burst rate and throughput
are both non-zero, the measurement interval, T, is
T=frCircuitCommittedBurst/frCircuitThroughput.
If the configured committed burst rate and throughput
are both zero, the measurement interval, T, is
T=frCircuitExcessBurst/ifSpeed."
REFERENCE
"American National Standard T1.617-1991, Section
6.5.19"
DEFVAL { 0 }
::= { frCircuitEntry 14 }
frCircuitMulticast OBJECT-TYPE
SYNTAX INTEGER {
unicast(1),
oneWay(2),
twoWay(3),
nWay(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates whether this VC is used as a unicast VC
(i.e. not multicast) or the type of multicast service
subscribed to"
REFERENCE
"Frame Relay PVC Multicast Service and Protocol
Description Implementation: FRF.7 Frame Relay Forum
Technical Committe October 21, 1994"
DEFVAL { unicast }
::= { frCircuitEntry 15 }
frCircuitType OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indication of whether the VC was manually created
(static), or dynamically created (dynamic) via the data
link control management interface."
::= { frCircuitEntry 16 }
frCircuitDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound frames dropped because of format
errors, or because the VC is inactive."
::= { frCircuitEntry 17 }
frCircuitReceivedDEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received from the network indicating
that they were eligible for discard since the virtual
circuit was created. This occurs when the remote DTE
sets the DE flag, or when in remote DTE's switch
detects that the frame was received as Excess Burst
data."
REFERENCE
"American National Standard T1.618-1991, Section 3.3.4"
::= { frCircuitEntry 18 }
frCircuitSentDEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames sent to the network indicating that
they were eligible for discard since the virtual
circuit was created. This occurs when the local DTE
sets the DE flag, indicating that during Network
congestion situations those frames should be discarded
in preference of other frames sent without the DE bit
set."
REFERENCE
"American National Standard T1.618-1991, Section
3.3.4"
::= { frCircuitEntry 19 }
frCircuitLogicalIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
-- Rsyntax INTEGER(1..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Normally the same value as frDlcmiIfIndex, but
different when an implementation associates a virtual
ifEntry with a DLC or set of DLCs in order to associate
higher layer objects such as the ipAddrEntry with a
subset of the virtual circuits on a Frame Relay
interface. The type of such ifEntries is defined by the
higher layer object; for example, if PPP/Frame Relay is
implemented, the ifType of this ifEntry would be PPP.
If it is not so defined, as would be the case with an
ipAddrEntry, it should be of type Other."
::= { frCircuitEntry 20 }
frCircuitRowStatus OBJECT-TYPE
SYNTAX RowStatus
-- Rsyntax INTEGER {
-- active(1),
-- notInService(2),
-- notReady(3),
-- createAndGo(4),
-- createAndWait(5),
-- destroy(6)
-- }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to create a new row or modify or
destroy an existing row in the manner described in the
definition of the RowStatus textual convention.
Writable objects in the table may be written in any
RowStatus state."
::= { frCircuitEntry 21 }
frErrTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrErrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table containing information about Errors on the
Frame Relay interface. Discontinuities in the counters
contained in this table are the same as apply to the
ifEntry associated with the Interface."
::= { frameRelayDTE 3 }
frErrEntry OBJECT-TYPE
SYNTAX FrErrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The error information for a single frame relay
interface."
INDEX { frErrIfIndex }
::= { frErrTable 1 }
FrErrEntry ::= SEQUENCE {
frErrIfIndex InterfaceIndex,
frErrType INTEGER,
frErrData OCTET STRING,
frErrTime TimeStamp,
frErrFaults Counter,
frErrFaultTime TimeStamp
}
frErrIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
-- Rsyntax INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex Value of the corresponding ifEntry."
::= { frErrEntry 1 }
frErrType OBJECT-TYPE
SYNTAX INTEGER {
unknownError(1),
receiveShort(2),
receiveLong(3),
illegalAddress(4),
unknownAddress(5),
dlcmiProtoErr(6),
dlcmiUnknownIE(7),
dlcmiSequenceErr(8),
dlcmiUnknownRpt(9),
noErrorSinceReset(10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of error that was last seen on this interface:
receiveShort: frame was not long enough to allow
demultiplexing - the address field was incomplete,
or for virtual circuits using Multiprotocol over
Frame Relay, the protocol identifier was missing
or incomplete.
receiveLong: frame exceeded maximum length configured for this
interface.
illegalAddress: address field did not match configured format.
unknownAddress: frame received on a virtual circuit which was not
active or administratively disabled.
dlcmiProtoErr: unspecified error occurred when attempting to
interpret link maintenance frame.
dlcmiUnknownIE: link maintenance frame contained an Information
Element type which is not valid for the
configured link maintenance protocol.
dlcmiSequenceErr: link maintenance frame contained a sequence
number other than the expected value.
dlcmiUnknownRpt: link maintenance frame contained a Report Type
Information Element whose value was not valid
for the configured link maintenance protocol.
noErrorSinceReset: no errors have been detected since the last
cold start or warm start."
::= { frErrEntry 2 }
frErrData OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..1600))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An octet string containing as much of the error packet
as possible. As a minimum, it must contain the Q.922
Address or as much as was delivered. It is desirable
to include all header and demultiplexing information."
::= { frErrEntry 3 }
frErrTime OBJECT-TYPE
SYNTAX TimeStamp
-- Rsyntax TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at which the error was
detected."
::= { frErrEntry 4 }
frErrFaults OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the interface has gone down since
it was initialized."
::= { frErrEntry 5 }
frErrFaultTime OBJECT-TYPE
SYNTAX TimeStamp
-- Rsyntax TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime at the time when the interface
was taken down due to excessive errors. Excessive
errors is defined as the time when a DLCMI exceeds the
frDlcmiErrorThreshold number of errors within
frDlcmiMonitoredEvents. See FrDlcmiEntry for further
details."
::= { frErrEntry 6 }
frTrapState OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates whether the system produces
the frDLCIStatusChange trap."
DEFVAL { disabled }
::= { frameRelayTrapControl 1 }
frTrapMaxRate OBJECT-TYPE
SYNTAX INTEGER(0..3600000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates the number of milliseconds
that must elapse between trap emissions. If events
occur more rapidly, the impementation may simply fail
to trap, or may queue traps until an appropriate time."
DEFVAL { 0 }
::= { frameRelayTrapControl 2 }
frDLCIStatusChange TRAP-TYPE
-- Reverse mappable trap
ENTERPRISE frameRelayDTE
VARIABLES {
frCircuitState }
-- Status
-- mandatory
DESCRIPTION
"This trap indicates that the indicated Virtual Circuit
has changed state. It has either been created or
invalidated, or has toggled between the active and
inactive states. If, however, the reason for the state
change is due to the DLCMI going down, per-DLCI traps
should not be generated."
::= 1
frPortGroup OBJECT IDENTIFIER ::= { frGroups 1 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The objects necessary to control the Link Management
-- Interface for a Frame Relay Interface as well as
-- maintain the error statistics on this interface.
-- objects
-- frDlcmiIfIndex, frDlcmiState, frDlcmiAddress,
-- frDlcmiAddressLen, frDlcmiPollingInterval,
-- frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold,
-- frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs,
-- frDlcmiMulticast, frDlcmiStatus, frDlcmiRowStatus
frCircuitGroup OBJECT IDENTIFIER ::= { frGroups 2 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The objects necessary to control the Virtual Circuits
-- layered onto a Frame Relay Interface.
-- objects
-- frCircuitIfIndex, frCircuitDlci, frCircuitState,
-- frCircuitReceivedFECNs, frCircuitReceivedBECNs,
-- frCircuitSentFrames, frCircuitSentOctets,
-- frCircuitReceivedFrames, frCircuitReceivedOctets,
-- frCircuitCreationTime, frCircuitLastTimeChange,
-- frCircuitCommittedBurst, frCircuitExcessBurst,
-- frCircuitThroughput, frCircuitMulticast, frCircuitType,
-- frCircuitDiscards, frCircuitReceivedDEs, frCircuitSentDEs,
-- frCircuitLogicalIfIndex, frCircuitRowStatus
frTrapGroup OBJECT IDENTIFIER ::= { frGroups 3 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The objects necessary to control a Frame Relay
-- Interface's notification messages.
-- objects
-- frTrapState, frTrapMaxRate
frErrGroup OBJECT IDENTIFIER ::= { frGroups 4 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- Objects designed to assist in debugging Frame Relay
-- Interfaces.
-- objects
-- frErrIfIndex, frErrType, frErrData, frErrTime, frErrFaults,
-- frErrFaultTime
frPortGroup0 OBJECT IDENTIFIER ::= { frGroups 6 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The objects necessary to control the Link Management
-- Interface for a Frame Relay Interface as well as
-- maintain the error statistics on this interface from
-- RFC 1315.
-- objects
-- frDlcmiIfIndex, frDlcmiState, frDlcmiAddress,
-- frDlcmiAddressLen, frDlcmiPollingInterval,
-- frDlcmiFullEnquiryInterval, frDlcmiErrorThreshold,
-- frDlcmiMonitoredEvents, frDlcmiMaxSupportedVCs,
-- frDlcmiMulticast
frCircuitGroup0 OBJECT IDENTIFIER ::= { frGroups 7 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The objects necessary to control the Virtual Circuits
-- layered onto a Frame Relay Interface from RFC 1315.
-- objects
-- frCircuitIfIndex, frCircuitDlci, frCircuitState,
-- frCircuitReceivedFECNs, frCircuitReceivedBECNs,
-- frCircuitSentFrames, frCircuitSentOctets,
-- frCircuitReceivedFrames, frCircuitReceivedOctets,
-- frCircuitCreationTime, frCircuitLastTimeChange,
-- frCircuitCommittedBurst, frCircuitExcessBurst,
-- frCircuitThroughput
frErrGroup0 OBJECT IDENTIFIER ::= { frGroups 8 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- Objects designed to assist in debugging Frame Relay
-- Interfaces from RFC 1315.
-- objects
-- frErrIfIndex, frErrType, frErrData, frErrTime
frTrapGroup0 OBJECT IDENTIFIER ::= { frGroups 9 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The objects necessary to control a Frame Relay
-- Interface's notification messages from RFC 1315.
-- objects
-- frTrapState
frNotificationGroup OBJECT IDENTIFIER ::= { frGroups 5 }
-- NOTIFICATION-GROUP
-- Status
-- mandatory
-- Descr
-- Traps which may be used to enhance event driven
-- management of the interface.
-- notifications
-- frDLCIStatusChange
frCompliance OBJECT IDENTIFIER ::= { frCompliances 1 }
-- MODULE-COMPLIANCE
-- Status
-- mandatory
-- Descr
-- The compliance statement
-- Module
-- >>current<<
-- MandGroup
-- frPortGroup
-- MandGroup
-- frCircuitGroup
-- OptGroup
-- frErrGroup
-- OptGroup
-- frTrapGroup
-- OptGroup
-- frNotificationGroup
-- ObjVar
-- frDlcmiRowStatus
-- ObjVar
-- frCircuitRowStatus
frCompliance0 OBJECT IDENTIFIER ::= { frCompliances 2 }
-- MODULE-COMPLIANCE
-- Status
-- mandatory
-- Descr
-- The compliance statement for objects and the trap
-- defined in RFC 1315.
-- Module
-- >>current<<
-- MandGroup
-- frPortGroup0
-- MandGroup
-- frCircuitGroup0
-- OptGroup
-- frErrGroup0
-- OptGroup
-- frTrapGroup0
-- OptGroup
-- frNotificationGroup
END