Notifications
You must be signed in to change notification settings - Fork 124
/
Copy pathCISCO-MGX82XX-VIRTUAL-PORT-MIB-V1SMI.my
611 lines (549 loc) · 17.5 KB
/
CISCO-MGX82XX-VIRTUAL-PORT-MIB-V1SMI.my
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
-- MIB file created 24-Oct-2002 19:29:34, by
-- SMICng version 2.2.11-beta(PRO)(Solaris), January 20, 2001. Enterprise key cisco.com
CISCO-MGX82XX-VIRTUAL-PORT-MIB DEFINITIONS ::= BEGIN
-- From file: "CISCO-MGX82XX-VIRTUAL-PORT-MIB.my"
-- Compile options "4 7 F H N W 03 06 0B 0G 0N 0T"
IMPORTS
virtualInterface
FROM BASIS-MIB
ciscoWan
FROM CISCOWAN-SMI
Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212;
ciscoMgx82xxVirtualPortMIB OBJECT IDENTIFIER ::= { ciscoWan 38 }
-- MODULE-IDENTITY
-- LastUpdated
-- 200208300000Z
-- OrgName
-- Cisco Systems, Inc.
-- ContactInfo
-- Cisco Systems
-- Customer Service
--
-- Postal: 170 W Tasman Drive
-- San Jose, CA 95134
-- USA
--
-- Tel: +1 800 553-NETS
--
-- E-mail: [email protected]
-- Descr
-- The MIB module for configuration ond reporting
-- statistics of virtual ports in PXM1 Service module
-- in MGX82xx series.
-- RevDate
-- 200208300000Z
-- RevDescr
-- Initial version of the MIB.
--
-- The content of this MIB was originally available
-- in CISCO-WAN-AXIPOP-MIB defined using SMIv1.
-- The applicable objects from CISCO-WAN-AXIPOP-MIB
-- are defined using SMIv2 in this MIB. Also the
-- descriptions of some of the objects have been
-- modified.
virtualInterfaceCnf OBJECT IDENTIFIER ::= { virtualInterface 1 }
virtualInterfaceCnt OBJECT IDENTIFIER ::= { virtualInterface 2 }
virtualInterfaceQbinCnf OBJECT IDENTIFIER ::= { virtualInterface 3 }
virtualInterfaceQbinCnt OBJECT IDENTIFIER ::= { virtualInterface 4 }
cmvPortMIBConformance OBJECT IDENTIFIER ::= { ciscoMgx82xxVirtualPortMIB 2 }
cmvPortMIBGroups OBJECT IDENTIFIER ::= { cmvPortMIBConformance 1 }
cmvPortMIBCompliances OBJECT IDENTIFIER ::= { cmvPortMIBConformance 2 }
vrtlIntrConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF VrtlIntrConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface Configuration Table."
::= { virtualInterfaceCnf 1 }
vrtlIntrConfigEntry OBJECT-TYPE
SYNTAX VrtlIntrConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Virtual Interface configuration Table."
INDEX { configVrtlIntrNum }
::= { vrtlIntrConfigTable 1 }
VrtlIntrConfigEntry ::= SEQUENCE {
configVrtlIntrNum INTEGER,
vrtlIntrPortNum INTEGER,
vrtlIntrState INTEGER,
vrtlIntrMaxQueMem INTEGER,
vrtlIntrMinCellRate INTEGER,
vrtlIntrMaxCellRate INTEGER,
vrtlIntrCurrConfigPaths INTEGER
}
configVrtlIntrNum OBJECT-TYPE
SYNTAX INTEGER(1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Number. There are totaly.
32 Virtual Interfaces on the card (egress)."
::= { vrtlIntrConfigEntry 1 }
vrtlIntrPortNum OBJECT-TYPE
SYNTAX INTEGER(0..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port number which will be connected to the
Virtual Interface. Value zero meens that this
virtual interface is not connected to any port."
::= { vrtlIntrConfigEntry 2 }
vrtlIntrState OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface State."
::= { vrtlIntrConfigEntry 3 }
vrtlIntrMaxQueMem OBJECT-TYPE
SYNTAX INTEGER(1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface's Max queue memory.
1 = 4Kcells
2 = 8Kcells
3 = 16Kcells
4 = 32Kcells
5 = 64Kcells
6 = 128Kcells
7 = 256Kcells
8 = 512Kcells."
::= { vrtlIntrConfigEntry 4 }
vrtlIntrMinCellRate OBJECT-TYPE
SYNTAX INTEGER(103384..353208)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface's minimum cell rate.
The default value:
for OC12 port is 1412832 cells/sec
for OC3 port is 353208 cells/sec
for T3 port is 96000 cells/sec
for E3 port is 80000 cells/sec"
::= { vrtlIntrConfigEntry 5 }
vrtlIntrMaxCellRate OBJECT-TYPE
SYNTAX INTEGER(103384..353208)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface's maximum cell rate.
The default value:
for OC12 port is 1412832 cells/sec
for OC3 port is 353208 cells/sec
for T3 port is 96000 cells/sec
for E3 port is 80000 cells/sec"
::= { vrtlIntrConfigEntry 6 }
vrtlIntrCurrConfigPaths OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is not a configurable parameter.
This gives the count of paths currently configured on this
virtual interface."
::= { vrtlIntrConfigEntry 7 }
vrtlIntrCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF VrtlIntrCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface Counter32s Table."
::= { virtualInterfaceCnt 1 }
vrtlIntrCounterEntry OBJECT-TYPE
SYNTAX VrtlIntrCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Virtual Interface Counter32 Table."
INDEX { countVrtlIntrNum }
::= { vrtlIntrCounterTable 1 }
VrtlIntrCounterEntry ::= SEQUENCE {
countVrtlIntrNum INTEGER,
vrtlIntrTotalCellCnt Counter,
vrtlIntrTotalQbinCellCnt Counter,
vrtlIntrRxdValidOAMCellCnt Counter,
vrtlIntrRxdRmCellCnt Counter,
vrtlIntrRxdClpUntaggedCellCnt Counter,
vrtlIntrRxdClpTaggedCellCnt Counter,
vrtlIntrRxdClpUntaggedDiscardedCellCnt Counter,
vrtlIntrRxdClpTaggedDiscardedCellCnt Counter,
vrtlIntrXmtdOAMCellCnt Counter,
vrtlIntrXmtdRmCellCnt Counter,
vrtlIntrXmtdClpUntaggedCellCnt Counter,
vrtlIntrXmtdClpTaggedCellCnt Counter
}
countVrtlIntrNum OBJECT-TYPE
SYNTAX INTEGER(1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Number."
::= { vrtlIntrCounterEntry 1 }
vrtlIntrTotalCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"
Total number of cells (VC plus Qbin) that belong to
this Virtual Interface."
::= { vrtlIntrCounterEntry 2 }
vrtlIntrTotalQbinCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of cells in the Qbin belonging
to this Virtual Interface."
::= { vrtlIntrCounterEntry 3 }
vrtlIntrRxdValidOAMCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of OAM cell received."
::= { vrtlIntrCounterEntry 4 }
vrtlIntrRxdRmCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of RM cells Received."
::= { vrtlIntrCounterEntry 5 }
vrtlIntrRxdClpUntaggedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of CLP-0 cells Received."
::= { vrtlIntrCounterEntry 6 }
vrtlIntrRxdClpTaggedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of CLP-1 cells Received."
::= { vrtlIntrCounterEntry 7 }
vrtlIntrRxdClpUntaggedDiscardedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of CLP-0 cells discarded at Ingress."
::= { vrtlIntrCounterEntry 8 }
vrtlIntrRxdClpTaggedDiscardedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of CLP-1 cells discarded at Ingress."
::= { vrtlIntrCounterEntry 9 }
vrtlIntrXmtdOAMCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of OAM cells transmitted."
::= { vrtlIntrCounterEntry 10 }
vrtlIntrXmtdRmCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of RM(Resource Monitoring)
cells transmitted."
::= { vrtlIntrCounterEntry 11 }
vrtlIntrXmtdClpUntaggedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of CLP-0 cells transmitted."
::= { vrtlIntrCounterEntry 12 }
vrtlIntrXmtdClpTaggedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of CLP-1 cells transmitted."
::= { vrtlIntrCounterEntry 13 }
vrtlIntrQbinConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF VrtlIntrQbinConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface QBin Configuration Table."
::= { virtualInterfaceQbinCnf 1 }
vrtlIntrQbinConfigEntry OBJECT-TYPE
SYNTAX VrtlIntrQbinConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Virtual Interface Qbin Config Table."
INDEX { queConfigVrtlIntrNum, queConfigVrtlIntrQbinNum }
::= { vrtlIntrQbinConfigTable 1 }
VrtlIntrQbinConfigEntry ::= SEQUENCE {
queConfigVrtlIntrNum INTEGER,
queConfigVrtlIntrQbinNum INTEGER,
vrtlIntrQbinState INTEGER,
vrtlIntrQbinPri INTEGER,
vrtlIntrQbinRate INTEGER,
vrtlIntrQbinDiscardSelection INTEGER,
vrtlIntrQbinMaxThreshold INTEGER,
vrtlIntrQbinClpHiThreshold INTEGER,
vrtlIntrQbinClpLoThreshold INTEGER,
vrtlIntrQbinFrameDiscardThreshold INTEGER,
vrtlIntrQbinEfciThreshold INTEGER
}
queConfigVrtlIntrNum OBJECT-TYPE
SYNTAX INTEGER(1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Virtual Interface Number."
::= { vrtlIntrQbinConfigEntry 1 }
queConfigVrtlIntrQbinNum OBJECT-TYPE
SYNTAX INTEGER(1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Virtual Interface Qbin Number. There are totaly 16 Qbin
per Virtual Interface."
::= { vrtlIntrQbinConfigEntry 2 }
vrtlIntrQbinState OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Virtual Interface QBIN state."
::= { vrtlIntrQbinConfigEntry 3 }
vrtlIntrQbinPri OBJECT-TYPE
SYNTAX INTEGER(1..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates the priority of the QBIN service
within the Virtual Interface."
::= { vrtlIntrQbinConfigEntry 4 }
vrtlIntrQbinRate OBJECT-TYPE
SYNTAX INTEGER(0..353208)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The rate at which cells in the QBIN are serviced.
Max Cell rate for OC3 interface is 353208 cell/sec."
::= { vrtlIntrQbinConfigEntry 5 }
vrtlIntrQbinDiscardSelection OBJECT-TYPE
SYNTAX INTEGER {
clpHysteresis(1),
frameDiscard(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" Virtual Interface QBin Congestion control option."
DEFVAL { clpHysteresis }
::= { vrtlIntrQbinConfigEntry 6 }
vrtlIntrQbinMaxThreshold OBJECT-TYPE
SYNTAX INTEGER(0..512000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Max cells that can be queued in the QBIN.
The Get value will be different from the Set
value because of FW internal round up."
::= { vrtlIntrQbinConfigEntry 7 }
vrtlIntrQbinClpHiThreshold OBJECT-TYPE
SYNTAX INTEGER(0..512000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold above which the tagged cells
will be dropped.
The Get value will be different from the Set
value because of FW internal round up."
::= { vrtlIntrQbinConfigEntry 8 }
vrtlIntrQbinClpLoThreshold OBJECT-TYPE
SYNTAX INTEGER(0..512000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Valid only if congestion control is set to
CLP hysterises. The threshold upto which the
dropping of the tagged cells should continue once
it has crossed CLP HI threshold.
The Get value will be different from the Set
value because of FW internal round up."
::= { vrtlIntrQbinConfigEntry 9 }
vrtlIntrQbinFrameDiscardThreshold OBJECT-TYPE
SYNTAX INTEGER(0..512000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Valid only if congestion control is set to
Frame Discard. It is the threshold after which
the QE will start discarding the entire frame
if one or more cells of the frame is discarded..
The Get value will be different from the Set
value because of FW internal round up."
::= { vrtlIntrQbinConfigEntry 10 }
vrtlIntrQbinEfciThreshold OBJECT-TYPE
SYNTAX INTEGER(0..512000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold above which the EFCI bits of
the cell is set.
The Get value will be different from the Set
value because of FW internal round up."
::= { vrtlIntrQbinConfigEntry 11 }
vrtlIntrQbinCounterTable OBJECT-TYPE
SYNTAX SEQUENCE OF VrtlIntrQbinCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Virtual Interface QBin Counter Table."
::= { virtualInterfaceQbinCnt 1 }
vrtlIntrQbinCounterEntry OBJECT-TYPE
SYNTAX VrtlIntrQbinCounterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Virtual Interface Qbin Counter Table.
Each entry contains information on the statistics supported
for an interface."
INDEX { queConuterVrtlIntrNum, queCounterVrtlIntrQbinNum }
::= { vrtlIntrQbinCounterTable 1 }
VrtlIntrQbinCounterEntry ::= SEQUENCE {
queConuterVrtlIntrNum INTEGER,
queCounterVrtlIntrQbinNum INTEGER,
vrtlIntrQbinCurrentCellCnt Counter,
vrtlIntrQbinRxdCellCnt Counter,
vrtlIntrQbinTxdCellCnt Counter,
vrtlIntrQbinDiscardedCellCnt Counter
}
queConuterVrtlIntrNum OBJECT-TYPE
SYNTAX INTEGER(1..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Virtual Interface Number."
::= { vrtlIntrQbinCounterEntry 1 }
queCounterVrtlIntrQbinNum OBJECT-TYPE
SYNTAX INTEGER(1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Virtual Interface Qbin Number. There are totaly 16 Qbin
per Virtual Interface."
::= { vrtlIntrQbinCounterEntry 2 }
vrtlIntrQbinCurrentCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Total number of cells currently in the Qbin."
::= { vrtlIntrQbinCounterEntry 3 }
vrtlIntrQbinRxdCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Total number of cells arrived to the QBIN."
::= { vrtlIntrQbinCounterEntry 4 }
vrtlIntrQbinTxdCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of cells departured from QBIN."
::= { vrtlIntrQbinCounterEntry 5 }
vrtlIntrQbinDiscardedCellCnt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of arrivals to QBIN which were discarded."
::= { vrtlIntrQbinCounterEntry 6 }
cmvPortConfGroup OBJECT IDENTIFIER ::= { cmvPortMIBGroups 1 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The collection of objects which are used for
-- configuring Virtual Ports in PXM1 service module.
-- objects
-- configVrtlIntrNum, vrtlIntrPortNum, vrtlIntrState,
-- vrtlIntrMaxQueMem, vrtlIntrMinCellRate, vrtlIntrMaxCellRate,
-- vrtlIntrCurrConfigPaths
cmvPortStatsGroup OBJECT IDENTIFIER ::= { cmvPortMIBGroups 2 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The collection of objects related to
-- statistics for Virtual Ports in PXM1 service module.
-- objects
-- countVrtlIntrNum, vrtlIntrTotalCellCnt,
-- vrtlIntrTotalQbinCellCnt, vrtlIntrRxdValidOAMCellCnt,
-- vrtlIntrRxdRmCellCnt, vrtlIntrRxdClpUntaggedCellCnt,
-- vrtlIntrRxdClpTaggedCellCnt,
-- vrtlIntrRxdClpUntaggedDiscardedCellCnt,
-- vrtlIntrRxdClpTaggedDiscardedCellCnt, vrtlIntrXmtdOAMCellCnt,
-- vrtlIntrXmtdRmCellCnt, vrtlIntrXmtdClpUntaggedCellCnt,
-- vrtlIntrXmtdClpTaggedCellCnt
cmvPortQbinConfGroup OBJECT IDENTIFIER ::= { cmvPortMIBGroups 3 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The collection of objects related to
-- configuration of Qbin related things in PXM1
-- service module.
-- objects
-- queConfigVrtlIntrNum, queConfigVrtlIntrQbinNum,
-- vrtlIntrQbinState, vrtlIntrQbinPri, vrtlIntrQbinRate,
-- vrtlIntrQbinDiscardSelection, vrtlIntrQbinMaxThreshold,
-- vrtlIntrQbinClpHiThreshold, vrtlIntrQbinClpLoThreshold,
-- vrtlIntrQbinFrameDiscardThreshold, vrtlIntrQbinEfciThreshold
cmvPortQbinStatsGroup OBJECT IDENTIFIER ::= { cmvPortMIBGroups 4 }
-- OBJECT-GROUP
-- Status
-- mandatory
-- Descr
-- The collection of objects related to
-- statistics for Qbin related things in PXM1
-- service module.
-- objects
-- queConuterVrtlIntrNum, queCounterVrtlIntrQbinNum,
-- vrtlIntrQbinCurrentCellCnt, vrtlIntrQbinRxdCellCnt,
-- vrtlIntrQbinTxdCellCnt, vrtlIntrQbinDiscardedCellCnt
cmvPortCompliance OBJECT IDENTIFIER ::= { cmvPortMIBCompliances 1 }
-- MODULE-COMPLIANCE
-- Status
-- mandatory
-- Descr
-- The compliance statement for objects related
-- to SRM MIB.
-- Module
-- >>current<<
-- MandGroup
-- cmvPortConfGroup
-- MandGroup
-- cmvPortStatsGroup
-- MandGroup
-- cmvPortQbinConfGroup
-- MandGroup
-- cmvPortQbinStatsGroup
END