Notifications
You must be signed in to change notification settings - Fork 0
/
LICOR.pas
607 lines (562 loc) · 23.2 KB
/
LICOR.pas
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
Unit licor;
{$L-}
{$R+} {Range checking on}
{$B+} {Boolean complete evaluation on}
{$S+} {Stack checking on}
{$I+} {I/O checking on}
{$N+} {Numeric coprocessor}
{$E-} {Do not include emulation code}
{*E+} {Include emulation code}
{$H-} {Old Turbo-style strings are default}
{
Read in data from a LiCor IRGA using its RS232 communications port.
v1.0 97/05/08 Original for LICOR 6252/62 through serial BIOS or duTec
v1.1 97/07/10 Replace '\13' by correct '\' = CR+LF for cr when using
duTec. Just a '/13' did not seem to be enough.
v1.2 98/02/09 Increase number of possible units to 13.
For up to six rings, this will allow 6 treatment IRGA's,
six control ring IRGA's, and an ambient multiport.
v1.3 98/04/19 Change from Uses ser95 to ser98.
v1.4 98/05/02 Add 'auto_print' to licor record.
Initialize licor with variable auto_print rather than 0.
Don't issue remote print command if auto_print > 0.0.
v1.5 98/05/03 Define global 'licor6262_toggle' BOOLEAN.
v1.6 98/07/01 TEMP-TN patches.
v1.7 98/07/03 a) declare 'read_yet' in type licor6262_type.
b) initialize 'read_yet' to FALSE.
c) reenable optomux_debug output of error code and msg.
d) add list of error messages.
e) remove licor6262_toggle.
f) declare count_rest & count current initialize to 0.
g) new procedure licor6262_input.
h) implement "read_yet" and "count_rest" features.
i) previous errcode returned if a read is skipped.
j) new procedure licor6262_clear (sets read_yet = FALSE).
v1.8 98/07/25 licor6262_input(): fix already_read & address logic bug
v1.9 --was none--
v2.0 98/09/12 a) Delete CONST licor6262_idmax.
b) Add CONST licor6262_addr_min = $00.
c) Add CONST licor6262_addr_max = $FF.
d) Change licor6262_type to just one record, not an array.
e) Change licor6262_ptr to a pointer to a
static array of _type pointers.
f) An intermediate type licor6262_ptrray was required.
g) INIT: allocate licor6262_ptr & set all ^[] := NIL.
h) licor6262_alloc(): new procedure (includes old INIT).
i) licor6262_clear(): modified for id range, etc.
j) licor6262_parse(): remove special TN code.
k) all procedures: modify for new data structure.
l) licor6262_input(): vars j, already_read not needed.
98/09/13 m) Add PROCEDURE licor6262_show (addr).
n) Add Uses Crt; for the ClrScr call.
98/09/24 o) licor6262_init(): add errcode_save := err;
p) noinit renamed licor6262_noinit and put in Interface.
98/09/25 q) licor6262_clear(): NIL protection added.
98/09/27 r) Add PROCEDURE licor6262_addcode (addr, code, err).
s) Add FUNCTION licor6262_getvalue (addr, code, err).
98/09/29 t) Add CONST valid_codes=[ .. ].
99/09/10 u) licor6262_clear(): should be id < 0, not = 0.
00/01/18 v) Delphi 4 capability (crt32 and $H-)
v2.1 00/06/15 a) Limit valid address range to 00 - 1F (duTec masters)
b) Hardcoded this range in error message <--
c) Array of pointers still 0..255 initialized to NIL
d) After allocating record, set error to "not init"
e) licor6262_init: abandon serial attempts at first error
v3.0 02/03/22 a) Uses ser instead of ser98
b) Remove $IFDEF TURBO code and $IFDEF DELPHI
v3.1 02/12/06 a) [Some change not detailed in notebook or recorded here]
v4.0 04/08/01 a) Change all licor6262_* identifiers to licor_*
b) Recognize new "channel" 22 for LiCor 820/840 IRGA's
c) licor_type: add model: Word (set to 21 or 22)
d) licor_model_set: new; includes new error #10
04/08/04 e) init_DS_6262, init_DS_840: new, called by licor_init
f) count_rest now set to 50 or 0 (off) in _6262 or _840
g) licor_init, licor_read: modified for 62xx vs 8xx use
04/08/05 h) xml2dutec: new for LI820/LI840 use
04/08/25 i) xml2dutec, licor_read: P cmd OK; PP not needed; see NB
04/12/03 j) supress program init of li820/840 for now -- do otherwise
04/12/04 k) Add Windows to Uses list to pick up Sleep(ms)
licor_read: IF model 22, Sleep(100) between 'O' and 'P'
licor_read: do a 'PP' loop for trash removal
reinstate program init of li820/840
licor_init: power_up_clear of master address
v5.0 05/01/06 a) licor_read: trash removal only if LI8xx
b) use code 22 for LI820 and code 24 for LI840
c) xml2dutec: handle both 820 and 840 root nodes now
d) init_DS_840: handle LI840 water vapor as well
v5.1 05/10/07 e) init_DS_840: add <RAW>FALSE<RAW>
f) add 99 to valid_codes set (a dummy needed for LI840)
v6.0 09/08/10 a) Delete serial bios support
b) Error returns now of form -9990+errcode
v7.0 13/12/17 a) init_DS_840: nchcodes := 4 if LI820, := 5 if LI840
v7.1 13/12/19 a) init_DS_840: comment out configuration commands to IRGA
Configuration must be done offline by LI840Cfg
Done to reduce comm traffic under error conditions and
doesn't seem to work completely anyway
John Nagy, Brookhaven National Lab, Upton NY 11973 U.S.A.
}
Interface
Uses Windows, crt32, optomux;
CONST licor_addr_min = $00; {Address address range 0}
licor_addr_max = $1F; {reasonable for duTec master addresses}
licor_noinit = '??';
licor_errmsg: ARRAY [0..12] OF String[48] = (
{errcode message}
{ 0} 'No error',
{ 1} 'Address is out-of-range 0 to 31 (0x00 - 0x1F)',
{ 2} 'Failure to allocate memory for record',
{ 3} 'Record with this address not allocated',
{ 4} 'Requested LiCor variable code not valid',
{ 5} 'Number of codes requested exceeds max',
{ 6} 'Unit with this address not initialized',
{ 7} 'Unrecognized DAQC type',
{ 8} 'Illegal character in LiCor returned string',
{ 9} 'Insufficient number of returned values',
{10} 'This LiCor ID already allocated to another model',
{11} 'Serial BIOS error',
{12} 'Optomux error');
nchmax = 5;
valid_codes = [21..27, 29, 31..39, 41..47, 49, 99];
TYPE licor_type = RECORD
daqc: String[8];
port,
address,
model, {21->6252/6262 22->820 24->840}
speed: Word;
auto_print: REAL;
read_yet: BOOLEAN;
nchcodes: Byte;
chcode: ARRAY [1..nchmax] OF Byte;
value: ARRAY [1..nchmax] OF REAL;
count_rest,
count_current: INTEGER;
errcode_save: INTEGER;
END;
licor_ptrray =
ARRAY [0..255] OF ^licor_type;
VAR licor_ptr: ^licor_ptrray;
PROCEDURE licor_init (id: INTEGER; VAR errcode: INTEGER);
PROCEDURE licor_read (id: INTEGER; VAR errcode: INTEGER);
PROCEDURE licor_input (id: INTEGER; VAR errcode: INTEGER);
PROCEDURE licor_alloc (id: INTEGER; VAR errcode: INTEGER);
PROCEDURE licor_addcode (id, code: INTEGER; VAR errcode: INTEGER);
PROCEDURE licor_model_set (id, channel: INTEGER; VAR errcode: INTEGER);
PROCEDURE licor_clear (id: INTEGER);
PROCEDURE licor_show (id: INTEGER);
FUNCTION licor_getvalue (id, code: INTEGER; VAR errcode: INTEGER): REAL;
Implementation
VAR err: BOOLEAN;
msg: String;
PROCEDURE licor_alloc (id: INTEGER; VAR errcode: INTEGER);
{Allocates memory for record with address = id}
BEGIN
errcode := 0;
IF (id < licor_addr_min) OR (id > licor_addr_max)
THEN errcode := 1;
IF (errcode = 0) THEN BEGIN
IF (licor_ptr^[id] = NIL) THEN BEGIN
NEW (licor_ptr^[id]);
IF (licor_ptr^[id] = NIL) THEN errcode := 2;
IF (errcode = 0) THEN WITH licor_ptr^[id]^ DO BEGIN
daqc := licor_noinit;
port := 0;
address := id;
speed := 0;
model := 0;
auto_print := 0.0;
read_yet := FALSE;
nchcodes := 0;
count_rest := 0;
count_current := 0;
errcode_save := 6;
END; {fill fields of new record}
END; {allocating new (previously undefined) record}
END; {record allocation request with address valid}
END; {of procedure 'licor_alloc'}
PROCEDURE licor_addcode (id, code: INTEGER; VAR errcode: INTEGER);
{Adds LiCor variable code to list in record}
VAR i: INTEGER;
have: BOOLEAN;
BEGIN
errcode := 0;
IF (id < licor_addr_min) OR (id > licor_addr_max) THEN errcode := 1;
IF (errcode = 0) THEN BEGIN
IF (licor_ptr^[id] = NIL) THEN errcode := 3;
IF (errcode = 0) THEN BEGIN
IF NOT (Lo(code) IN valid_codes) THEN errcode := 4;
IF (errcode = 0) THEN WITH licor_ptr^[id]^ DO BEGIN
have := FALSE;
FOR i := 1 TO nchcodes DO
IF (code = chcode[i]) THEN have := TRUE;
IF NOT have THEN BEGIN
IF (nchcodes >= nchmax) THEN errcode := 5;
IF (errcode = 0) THEN BEGIN
INC (nchcodes);
chcode[nchcodes] := code;
value [nchcodes] := 6262;
END; {do it; number of max codes not exceeded}
END; {code not yet in list}
END; {fill code list in record}
END; {valid variable code}
END; {id in range}
END; {of procedure 'licor_addcode'}
PROCEDURE licor_model_set (id, channel: INTEGER; VAR errcode: INTEGER);
{Set which LiCor model this ID is}
BEGIN
errcode := 0;
IF (id < licor_addr_min) OR (id > licor_addr_max) THEN errcode := 1;
IF (errcode = 0) THEN BEGIN
IF (licor_ptr^[id] = NIL) THEN errcode := 3;
IF (errcode = 0) THEN WITH licor_ptr^[id]^ DO BEGIN
IF (model = 0) OR (model = channel)
THEN model := channel
ELSE errcode := 10;
END; {id allocated}
END; {id in range}
END; {of procedure 'licor_model_set'}
FUNCTION licor_getvalue (id, code: INTEGER; VAR errcode: INTEGER): REAL;
{Get a value (LiCor variable code) that has been read in}
VAR i, index: INTEGER;
BEGIN
errcode := 0;
index := 0;
IF (id < licor_addr_min) OR (id > licor_addr_max) THEN errcode := 1;
IF (errcode = 0) THEN BEGIN
IF (licor_ptr^[id] = NIL) THEN errcode := 3;
IF (errcode = 0) THEN BEGIN
IF NOT (Lo(code) IN valid_codes) THEN errcode := 4;
IF (errcode = 0) THEN WITH licor_ptr^[id]^ DO BEGIN
FOR i := 1 TO nchcodes DO IF (code = chcode[i]) THEN index := i;
IF NOT (index IN [1..nchcodes]) THEN errcode := 5;
END;
END; {record was allocated}
END; {id in range}
IF (errcode = 0)
THEN licor_getvalue := licor_ptr^[id]^.value[index]
ELSE licor_getvalue := -(9990+errcode);
END; {of function 'licor_getvalue'}
PROCEDURE licor_clear (id: INTEGER);
{Set one selected or all (id < 0) read_yet to FALSE}
VAR i, mn, mx: INTEGER;
BEGIN
IF id < 0
THEN BEGIN mn := licor_addr_min; mx := licor_addr_max; END
ELSE BEGIN mn := id; mx := id; END;
FOR i := mn TO mx DO
IF (licor_ptr^[i] <> NIL)
THEN licor_ptr^[i]^.read_yet := FALSE;
END; {of procedure 'licor_clear'}
PROCEDURE licor_list (id: INTEGER; VAR msg: String);
{Construct the "Set print list" command for the LiCor 6252/6262}
VAR i: INTEGER;
field: String[16];
BEGIN
msg := '*13';
WITH licor_ptr^[id]^ DO FOR i := 1 TO nchcodes DO BEGIN
Str (chcode[i]:1, field);
msg := msg + field;
IF i <> nchcodes THEN msg := msg + ','
ELSE msg := msg;
END;
END; {of procedure 'licor_list'}
PROCEDURE init_DS_6262 (id: INTEGER; VAR err: BOOLEAN);
{6252/6262 specific initialization through duTec}
VAR arg: String;
VAR cr: String;
BEGIN
WITH licor_ptr^[id]^ DO BEGIN
count_rest := 50;
cr := '\';
IF auto_print <= 0.0
THEN arg := '0'
ELSE Str (auto_print:4:2, arg);
IF NOT err THEN BEGIN
dutec_out (port, address, '*14'+arg+cr); {auto print off}
err := err OR optomux_var.error;
END;
IF NOT err THEN BEGIN
dutec_out (port, address, '*150'+cr); {auto header none}
err := err OR optomux_var.error;
END;
licor_list (id, msg); {set up print list}
IF NOT err THEN BEGIN
dutec_out (port, address, msg+cr);
err := err OR optomux_var.error;
END;
IF NOT err THEN BEGIN
dutec_out (port, address, '*12'); {flush noise and buffers}
err := err OR optomux_var.error;
END;
END; {with}
END; {of procedure 'init_DS_6262'}
PROCEDURE xml2dutec (id: INTEGER; cmd: String; VAR err: BOOLEAN);
{Apply needed escapes to xml and send to LI-8xx through duTec}
VAR rootbegin, rootend: String;
msg, msg_escaped: String;
i: INTEGER;
BEGIN
IF licor_ptr^[id]^.model = 22 THEN BEGIN
rootbegin := '<LI820>';
rootend := '</LI820>';
END;
IF licor_ptr^[id]^.model = 24 THEN BEGIN
rootbegin := '<LI840>';
rootend := '</LI840>';
END;
IF licor_ptr^[id]^.model = 27 THEN BEGIN
rootbegin := '<LI850>';
rootend := '</LI850>';
END;
msg := rootbegin + cmd + rootend;
msg_escaped := '';
FOR i := 1 TO Length(msg) DO BEGIN
IF (ORD(msg[i]) = $0A) THEN msg_escaped := msg_escaped + '/0A' {LF}
ELSE IF (ORD(msg[i]) = $0D) THEN msg_escaped := msg_escaped + '/0D' {CR}
ELSE IF (ORD(msg[i]) = $2F) THEN msg_escaped := msg_escaped + '/2F' {/}
ELSE IF (ORD(msg[i]) = $3E) THEN msg_escaped := msg_escaped + '/3E' {>}
ELSE IF (ORD(msg[i]) = $5C) THEN msg_escaped := msg_escaped + '/5C' {\}
ELSE msg_escaped := msg_escaped + msg[i];
END;
err := FALSE;
WITH licor_ptr^[id]^ DO BEGIN
dutec_out (port, address, msg_escaped + '/0A');
err := err OR optomux_var.error;
{IF FALSE THEN BEGIN {removed for now...}
IF NOT err THEN BEGIN
dutec_in (port, address, 'PP', msg);
{err := err OR optomux_var.error;}
END;
{END; {...removed for now}
END; {with}
END; {of procedure 'xml2dutec'}
PROCEDURE init_DS_840 (id: INTEGER; VAR err: BOOLEAN);
{820/840 specific initialization through duTec
}
BEGIN
WITH licor_ptr^[id]^ DO BEGIN
count_rest := 0; {no resting}
{Override _addcode results}
nchcodes := 4; {LI820}
IF (model in [24, 27]) THEN nchcodes := 5; {LI840}
chcode[1] := 42; {Cell temperature oC}
chcode[2] := 43; {Cell pressure kPa}
chcode[3] := 22; {CO2 umol/mol=ppm}
chcode[4] := 99; {IVOLT}
chcode[5] := 32; {H2O mmol/mol=ppt}
{Comment out online configuration 2013-12-19 in SA...
xml2dutec (id, '<RS232><CO2>TRUE</CO2></RS232>', err);
xml2dutec (id, '<RS232><CO2ABS>FALSE</CO2ABS></RS232>', err);
IF model = 24 THEN BEGIN
xml2dutec (id, '<RS232><H2O>TRUE</H2O></RS232>', err);
xml2dutec (id, '<RS232><H2ODEWPOINT>FALSE</H2ODEWPOINT></RS232>', err);
xml2dutec (id, '<RS232><H2OABS>FALSE</H2OABS></RS232>', err);
END;
xml2dutec (id, '<RS232><CELLTEMP>TRUE</CELLTEMP></RS232>', err);
xml2dutec (id, '<RS232><CELLPRES>TRUE</CELLPRES></RS232>', err);
xml2dutec (id, '<RS232><IVOLT>TRUE</IVOLT></RS232>', err);
xml2dutec (id, '<RS232><RAW>FALSE</RAW></RS232>', err);
xml2dutec (id, '<RS232><ECHO>FALSE</ECHO></RS232>', err);
xml2dutec (id, '<RS232><STRIP>TRUE</STRIP></RS232>', err);
xml2dutec (id, '<CFG><OUTRATE>0.0</OUTRATE></CFG>', err);
xml2dutec (id, '<CFG><HEATER>TRUE</HEATER></CFG>', err);
xml2dutec (id, '<CFG><PCOMP>TRUE</PCOMP></CFG>', err);
xml2dutec (id, '<CFG><FILTER>0</FILTER></CFG>', err);
...end commenting out}
END; {with}
END; {of procedure 'init_DS_840'}
PROCEDURE licor_init (id: INTEGER; VAR errcode: INTEGER);
BEGIN
err := FALSE;
errcode := 0;
IF id IN [licor_addr_min..licor_addr_max]
THEN WITH licor_ptr^[id]^ DO BEGIN
read_yet := FALSE;
count_current := 0;
IF daqc = 'SB' THEN BEGIN {serial bios direct}
END ELSE
IF daqc = 'DS' THEN WITH optomux_var DO BEGIN
{duTec DAQC using optomux/comm_dp4 communications drivers}
power_up_clear (port, address);
dutec_speed (port, address, speed); {duTec port speed only}
err := err OR optomux_var.error;
CASE model OF
21: init_DS_6262 (id, err);
22,
24,
27: init_DS_840 (id, err);
END; {case}
IF err THEN errcode := 12; {optomux error has occurred}
errcode_save := errcode;
END ELSE
IF daqc = licor_noinit THEN BEGIN
errcode := 6; {unit id has not been initialized}
END ELSE
errcode := 7; {unrecognized daqc type}
END
ELSE errcode := 1; {id out-of-range}
END; {procedure 'licor_init'}
PROCEDURE licor_parse (id: INTEGER; msg: String; VAR errcode: INTEGER);
{Put ascii fields into array of float}
CONST numeric = ['0'..'9','+','-','.','e','E'];
VAR i,j: INTEGER;
field: String[16];
valcode: INTEGER;
BEGIN
i := 1;
j := 0;
WITH licor_ptr^[id]^ DO BEGIN
WHILE (i <= Length(msg)) AND (j < nchcodes) DO BEGIN
field := '';
WHILE NOT (msg[i] IN numeric) DO INC(i);
WHILE (i <= Length(msg)) AND (msg[i] IN numeric) DO BEGIN
field := field + msg[i];
INC(i);
END;
Val (field, value[j+1], valcode);
IF (valcode <> 0) THEN errcode := 8; {probably invalid character}
{*** debugging -- replace by LiCor debugging, not Optomux
IF optomux_debug AND (errcode = 8) THEN
WRITELN (i:3, j+1:3, '\', msg, '\', field, '\');
***}
INC (j);
END;
IF (errcode = 0) AND (j < nchcodes) THEN errcode := 9; {too few}
END; {of with}
END; {of procedure 'licor_parse'}
PROCEDURE licor_read (id: INTEGER; VAR errcode: INTEGER);
VAR j: INTEGER;
cmd: String;
BEGIN
err := FALSE;
errcode := 0;
msg := '';
IF id IN [licor_addr_min..licor_addr_max]
THEN WITH licor_ptr^[id]^ DO BEGIN
FOR j := 1 TO nchcodes DO value[j] := -888.0;
IF daqc = 'SB' THEN BEGIN {serial bios direct}
END ELSE
IF daqc = 'DS' THEN WITH optomux_var DO BEGIN
{duTec DAQC using optomux/comm_tp4 communications drivers}
IF auto_print <= 0.0 THEN BEGIN
IF model IN [22,24,27] THEN REPEAT {discard any trash -- LI8xx only}
dutec_in (port, address, 'PP', msg);
UNTIL (msg = '');
CASE model OF
21: cmd := '*12';
22: cmd := '<LI820/3E<DATA/3E?</2FDATA/3E</2FLI820/3E/0A';
24: cmd := '<LI840/3E<DATA/3E?</2FDATA/3E</2FLI840/3E/0A';
27: cmd := '<LI850/3E<DATA/3E?</2FDATA/3E</2FLI850/3E/0A';
END; {case}
dutec_out (port, address, cmd);
err := err OR optomux_var.error;
END;
IF (model IN [22,24,27]) THEN Windows.Sleep (100);
dutec_in (port, address, 'P', msg);
err := err OR optomux_var.error;
IF NOT err
THEN licor_parse (id, msg, errcode)
ELSE errcode := 12; {optomux error has occurred}
END ELSE
IF daqc = licor_noinit THEN BEGIN
errcode := 6; {unit id has not been initialized}
END ELSE
errcode := 7; {unrecognized daqc type}
errcode_save := errcode;
END
ELSE errcode := 1; {id out-of-range}
{*** Echo non-zero error code if optomux debug on ...
--replace this by LiCor debugging, not Optomux
IF optomux_debug AND (errcode <> 0)
THEN WRITELN ('Errcode = ',errcode:1, ' ', licor_errmsg[errcode]);
... move this line to enable/disable echo ***}
END; {procedure 'licor_read'}
PROCEDURE licor_input (id: INTEGER; VAR errcode: INTEGER);
{This procedure is an (optional) front porch for licor_read.
It implements two features:
(1) Not reading the LiCor every N'th sampling interval so that the
LiCor program loop can get everything done occasionally, such
as updating the cell temperature value. Calling program has
responsibility for setting .count_rest = N during initialization.
(2) Checking to see if the LiCor has already been read this sampling
interval. Calling program has responsibility of calling
licor_clear() at beginning of sampling procedure.
Both features depend on data in buffer and flags being undisturbed.}
BEGIN
WITH licor_ptr^[id]^ DO
IF NOT read_yet
THEN IF (count_current <= count_rest)
THEN BEGIN
licor_read (id, errcode);
read_yet := TRUE;
IF (count_rest > 0) THEN INC (count_current);
END
ELSE BEGIN
count_current := 0;
read_yet := TRUE;
errcode := errcode_save;
END
ELSE BEGIN {get previously read values}
errcode := errcode_save;
END;
END; {procedure 'licor_input'}
PROCEDURE licor_show (id: INTEGER);
{Displays status and contents of licor records.}
VAR i, j: INTEGER;
colorsave: INTEGER;
BEGIN
ClrScr;
IF (id < 0) THEN BEGIN {show matrix of allocated licor records}
WRITELN ('MATRIX SHOWING ACTIVE LICOR RECORDS');
WRITELN;
colorsave := TextAttr;
TextColor (Yellow);
WRITE (' ':10);
FOR i := 0 TO $F DO WRITE (' x', word2hex(i,2,2):2);
WRITELN;
FOR j := 0 TO $F DO BEGIN
IF ((j MOD 4) = 0) THEN WRITELN;
TextColor (Yellow);
WRITE ('x', word2hex(16*j,2,2), ' ':7);
FOR i := 0 TO $F DO
IF (licor_ptr^[16*j+i] <> NIL)
THEN BEGIN TextColor (LightRed); WRITE ('X':4); END
ELSE BEGIN TextColor (LightGreen); WRITE ('-':4); END;
WRITELN;
END;
TextColor (colorsave);
END;
IF (id >= licor_addr_min) AND (id <= licor_addr_max) THEN BEGIN
WRITELN ('CONTENTS OF SELECTED LICOR RECORD');
WRITELN;
IF (licor_ptr^[id] <> NIL) THEN WITH licor_ptr^[id]^ DO BEGIN
WRITELN ('DAQC TYPE: ', daqc:8);
WRITELN ('PORT: ', port:8);
WRITELN ('ADDRESS: ', word2hex(address,2,4):8, 'h =', address:3);
WRITELN ('SPEED: ', speed:8);
WRITELN ('MODEL: ', model:8);
WRITELN ('AUTO PRINT: ', auto_print:8:2);
WRITELN ('READ YET: ', read_yet:8);
WRITELN ('N CODES: ', nchcodes:8);
WRITE ('CODE: ');
FOR i := 1 TO nchcodes DO WRITE (chcode[i]:8);
WRITELN;
WRITE ('VALUE: ');
FOR i := 1 TO nchcodes DO WRITE (value[i]:8:2);
WRITELN;
WRITELN ('COUNT REST: ', count_rest:8);
WRITELN ('COUNT CURRENT:', count_current:8);
WRITELN ('LAST ERRCODE: ', errcode_save:8);
WRITELN ('LAST MESSAGE: ', licor_errmsg[errcode_save]);
END
ELSE WRITELN ('RECORD AT ADDRESS ', word2hex(id,2,2):2,
'h NOT YET ALLOCATED!');
END;
END; {procedure 'licor_show'}
{initialization of unit}
VAR i: INTEGER;
BEGIN
NEW (licor_ptr);
FOR i := 0 TO 255 DO
licor_ptr^[i] := NIL;
{of unit 'licor'...}
END.