I was just checking the Ryan (1991) leaf maintenance respiration subroutine, and I noticed that the reference value at 25°C is calculated from the original reference at 20°C using a Q10 = 1.5
Perhaps we would want to use the same value in both cases? I have the impression this is making the reference respiration to be less than intended for C4 grasses...
The text was updated successfully, but these errors were encountered:
I was just checking the Ryan (1991) leaf maintenance respiration subroutine, and I noticed that the reference value at 25°C is calculated from the original reference at 20°C using a Q10 = 1.5
fates/biogeophys/FatesPlantRespPhotosynthMod.F90
Lines 2105 to 2106 in 5551a70
However, when the respiration is calculated for C4 grasses, the actual Q10 used is 2.0:
fates/biogeophys/FatesPlantRespPhotosynthMod.F90
Lines 2121 to 2123 in 5551a70
Perhaps we would want to use the same value in both cases? I have the impression this is making the reference respiration to be less than intended for C4 grasses...