Skip to content

Commit 5fb3705

Browse files
authored
Update to unable to connect to NDX guidance
Mention of VNC over RDP, and inclusion of options for DRAC restart after an in-cycle call lead to confusion
1 parent 2f86270 commit 5fb3705

File tree

1 file changed

+5
-2
lines changed

1 file changed

+5
-2
lines changed

doc/Providing-Support.md

Lines changed: 5 additions & 2 deletions
Original file line numberDiff line numberDiff line change
@@ -97,9 +97,12 @@ There are a number of tips for [trouble shooting](#all_troubleshooting_links) al
9797
- out of hours, if in cycle then in zoom phone call "ISIS IT Infrastructure on-call" (phone number 94499)
9898
- If attempting to connect to EMMA, remember the -A
9999
1. Unable to connect to NDX via RDP
100-
- Try yourself to RDP, if you can ask reporter to try again, if they can't it is a connectivity issue for the system they are using to site, in hours refer them to the service desk, out of hours this is best efforts. Check the ISIS Computing O365 SharePoint for more information.
100+
- This is no longer an option, please use VNC
101+
- If they don't know the password, check that they are an instrument scientist with appropriate access to the information required. If they are not an instrument scientist ask them to contact their local contact to resolve this. If they are, add them to the appropriate group if they are the local contact for this experiment
102+
1. Unable to connect to NDX via VNC
101103
- Check ping to the NDX, and to the NDH
102-
- If there are any issues with these pings, you can check DRAC. [Basic DRAC information here](https://stfc365.sharepoint.com/sites/ISISExperimentControls/SitePages/Getting%20to%20Instrument%20DRACs.aspx) and instrument [DRAC IDs here](https://stfc365.sharepoint.com/sites/ISISExperimentControls/Lists/Instrument%20Control%20Computers/AllItems.aspx).
104+
- If there are any issues with these pings, you can check DRAC. [Basic DRAC information here](https://stfc365.sharepoint.com/sites/ISISExperimentControls/SitePages/Getting%20to%20Instrument%20DRACs.aspx) and instrument [DRAC IDs here](https://stfc365.sharepoint.com/sites/ISISExperimentControls/Lists/Instrument%20Control%20Computers/AllItems.aspx). It is worth following the DRAC connections
105+
- If you are restarting via the DRAC, using `power cycle system (cold reboot)` shoule bring the system back
103106
1. Wrong password entered too many times on anything other than NDX
104107
- We can't resolve this
105108
</details>

0 commit comments

Comments
 (0)