Read this only if you change msgen/wiring/simset internals. Building circuits needs only SKILL.md.
"MSMCompressedElectronicsWorkbenchXML" 36-byte signature (project .ewprj: "CompressedElectronicsWorkbenchXML", 33 bytes)
u32 total uncompressed length, u32 0
repeat: u32 block length, u32 compressed length, PKWARE DCL "implode" data (≤ 900 000 bytes per block, blocks independent)
- DCL header
01 06: ASCII mode (Huffman-coded literals), 4 KB dictionary. - Decompression follows Mark Adler's
zlib/contrib/blast/blast.c; compression is a greedy LZ77 written for this project. Multisim reads our output (verified on every sample). Container layout first documented by barncastle's converter gist4277ac44aa47bf8c4389c7df0d160e56(which needs the commercial IMPLODE.DLL; we don't). - Payload:
<?xml version="1.0" encoding="ASCII"?>+<MSMElectronicsWorkbench Schema="67">. Multisim also opens the uncompressed XML directly. - Some samples carry
\x00inside attribute values; strip before parsing (msxml.parsedoes).
&ASCtext— plain ASCII.&UNItext— non-ASCII characters written_uc1XXXX(4 hex digits):10k_uc103a9=10kΩ,_uc100b5=µ. Any language works for titles (msgen.enc).- Newlines inside attribute values must be literal newlines. SPICE templates, multi-line
.MODELtext and the simulation settings rely on them. Multisim does not decode numeric character references ( ): the file still opens and the netlist report is still right, but every resistor's template collapses into one garbled line and simulates as ~0 Ω. Only& < > "are safe. Python's XML parser, conversely, normalises literal newlines in attributes to spaces — somsxml.fromstringturns them into character references before parsing andwiring.dumpturns them back into literal newlines when writing.
Objects— top-level visible objects:CIITSymbolComp— a part symbol.CiComponent→ its electrical record;InstanceRefDes= refdes. Children:CIITSymTextCompName/Value(labels), graphics,CIITSymbolBorderRect(body box),CIITPinSymbolComp(pins;PortID→ CiPort) each holding aCIITPinConnectorComp(ptCenterX/Y,ConnectListof wire ends).CIITLinkComp— a wire.Points= absolute polyline;Connect1/Connect2= ids of its two end objects;Node/NodeTextmay be 0;ElectricalObject/ModifierInfo/Element NetModifier="&ASCNI_EWB_NET_NAME"names the net (use a real random GUID per net name — made-up GUIDs make Multisim draw that net in black).CODPinComp(in Objects) — a junction dot. Absolute position =CenterX/Y+ its own M20/M21.Mobility="0";ConnectList= the wire ends attached to it.CIITProbeExtComponent— a probe. No wires: the net is whatever wire passes through its position.CODTextComp— free text.
ReferencedComponents— the wire-endCODPinComps (written in full,Mobility="1",Pen-Style="5"i.e. invisible pen, otherwise every pin gets a dot;ConnectList→ a pin connector or a junction) plus empty<Item ID= Class=/>back-references to wires, junctions and pin connectors.
CiComponent—LocalName(refdes),SymCompID,Model,Circuit.Attributeshold the SPICE template (CiaSpiceTmpltExprt),CiaParamList(doubles/parameters; R/C/L/VDC main value at index 1, VAC peak at 1 and frequency at 5),CiaCStrings (value and display strings) andCiaCollStrings (first list's first 4 items = family, e.g.RESISTOR|RESISTOR_VIRTUAL|RESISTOR|VIRTUAL_RESISTANCE).CiPort—Component→ its part;Nodesmay be empty.CiModel—Scope= circuit id; holds the.MODELtext.CiNode— nets. May all be deleted: Multisim rebuilds connectivity from the wires on load (verified with the netlist report and the DC operating point). msgen writes none.CiCircuit— master listsModels,Nodes,Components,ProbeExts(Item CiID=).
ViewState, NetLabels, CCompInstancePropManager may be dropped. In RefDesMgrs, entries for deleted parts must
go together: CIRToInfoMapItem (else a new part reusing a name inherits the old display name, e.g. probe PR1
shows up as V(Output)) and RefDesPrefixUsage (else Multisim thinks R1/Q1 are taken and renumbers new parts on
load — the netlist then no longer matches).
A custom nested text format key:type{value} (type ∈ list/string/double/long). simset.py parses/edits it.
Relevant blocks (any list holding both TSTOP and TMAX):
DEFAULT_INST_SETTINGS/TRAN/ANALYSIS— the interactive simulation (F5):TSTOP= 1e30.SIMULATION_INFO/ANALYSES/TRAN/ANALYSIS— Simulate ▸ Analyses ▸ Transient.…/FOUR|PSWEEP|TSWEEP|WORST|MONTE|TRACEWIDTH/…/Tran— transient settings embedded in other analyses.TMAX:string{calculate}≈ TSTOP/50.IC:string{auto_ic|zero_ic}. The COM simulation ignores TMAX but honours IC.
Item@ID/CiID, CiComponent@SymCompID/Model/Circuit, CIITSymbolComp@CiComponent, CIITPinSymbolComp@PortID,
CiPort@Component, CiModel@Scope, CIITLinkComp@Connect1/Connect2, CiProbeExtComp@SymCompID,
CIITProbeExtComponent@CiProbeExtComp. Colour attributes are long integers too — not ids. In some samples a
symbol's id and the component's SymCompID disagree: find the symbol via its CiComponent attribute.
Each object has Transformer-M00 M01 M10 M11 M20 M21, row-vector convention:
x' = x·M00 + y·M10 + M20, y' = x·M01 + y·M11 + M21. Pin position = symbol ∘ pin-symbol ∘ connector transform
applied to (ptCenterX, ptCenterY) — checked against all wire ends of a sample. Moving a part = changing the
symbol's own M20/M21. Multisim bakes rotation into the children, leaving the symbol matrix identity — so keep one
template per orientation instead of rotating.